2. Summary Table
2. Summary Table
Performance Characteristics
Model Code
Net
Weight
(lbs)
Capacity
Fan Speed
Airflow
(Cooling/Heating)
(CFM)
Sound Pressure Level
(dBA)
Sound Power Level
(dBA)
Cooling
(Btu/h)
Heating
(Btu/h)
CNH09
L
DB
(AC009BN
L
DCH/AA)
41.7
Max.
13,000
16,000
High
2
83
/
2
83
33
50
Std.
9,100
12,000
Mid
230
/
230
30
-
Min.
3,000
2,900
Low
194
/
194
26
-
CNH12
L
DB
(AC012BN
L
DCH/AA)
41.7
Max.
14,000
17,000
High
399
/
399
34
51
Std.
12,000
14,000
Mid
353
/
353
31
-
Min.
3,200
3,000
Low
300
/
300
27
-
CNH18
L
DB
(AC018BN
L
DCH/AA)
49.
4
Max.
22,000
25,000
High
600
/
600
35
52
Std.
18,000
20,000
Mid
459
/
459
32
-
Min.
5,500
3,000
Low
353
/
353
28
-
NOTE
•
Sound data is based on cooling operation.
Electric Characteristics
Model
Outdoor Unit
Input Current (Amperes)
Power Supply
Indoor Unit
Outdoor Unit
Rated
Voltage range
Outdoor Unit
Indoor
Unit
Total MCA(A) MOP(A)
Hz
Volts
Min. Max Cooling Heating
CNH09
L
DB (AC009BN
L
DCH/AA) CXH09ADB (AC009BXADCH/AA)
60
208 to 230 187 253
10.9
15
CNH12
L
DB (AC012BN
L
DCH/AA) CXH12ADB (AC012BXADCH/AA)
60
208 to 230 187 253
10.9
15
CNH18
L
DB (AC018BN
L
DCH/AA) CXH18ADB (AC018BXADCH/AA)
60
208 to 230 187 253
20.1
25
NOTE
•
MCA : Minimum circuit amperes
•
MOP: Maximum Overcurrent Protective Device
•
Select wire size based on the value of MCA
Slim Duct
8.74
8.74
17.94
8.74
8.74
17.94
1.06
1.06
1.06
9.
8
9.
8
1
9.
0