English
5-24
Alarm Detection Setup
●
Off : Sensor does not operate.
①
N.O(Normal Open) Sensor : Sensor remains open all the time and if closed,
an alarm will be issued. (A Contact)
➁
N.C(Normal Close) Sensor : Sensor remains closed all the time and if open,
an alarm will be issued. (B Contact)
●
Cam
It is used to set a camera that synchronizes with the current sensor.
The default setting follows the sensor number. A sensor can synchronize with multiple
cameras so multiple values can be selected. You can set a preset for each camera to
synchronize sensors with cameras. If a sensor triggers the corresponding camera, the
camera can show you the preset location.
●
Alarm-out
Sets the Alarm-Out when Alarm Sensor sounds.
5 Alarm Outs are supported un the present.
Choose an alarm-out that you want to synchronize with the current sensor.
Multi-selection is possible.
●
Duration
Sets the Alarm-Out Duration. Alarm-Out continues for the set value.
Off / 3sec / 5sec / 10sec / 20sec / 30sec / Continuous
●
In the case of the 2080/2082, 8-channel information comes up.
SHR-2160/2162/2080/2082-E-1 10/19/07 9:36 AM Page 5-24
Summary of Contents for SHR-2080
Page 1: ...Real Time DVR SHR 2160 2162 2080 2082 User s Manual English ...
Page 7: ...Chapter 1 Overview ...
Page 17: ...Chapter 2 Installation ...
Page 34: ......
Page 35: ...Chapter 3 Connecting with other devices ...
Page 37: ...English 3 2 SHR 2080 2082 ...
Page 46: ......
Page 47: ...Chapter 4 Live ...
Page 56: ......
Page 57: ...Chapter 5 Menu Setup ...
Page 92: ......
Page 93: ...Chapter 6 PTZ Camera Control ...
Page 102: ......
Page 103: ...Chapter 7 Recording ...
Page 107: ...Chapter 8 Search and Play ...
Page 118: ......
Page 119: ...Chapter 9 Smart Viewer ...
Page 141: ...English 9 22 Alarm Out Schedule You can change the alarming schedulerelated settings ...
Page 182: ......
Page 183: ...Appendix ...
Page 187: ...10 4 English 2Outline Drawings SHR 2160 SHR 2162 ...
Page 188: ...SHR 2160 2162 2080 2082 USER S MANUAL 10 5 English SHR 2080 SHR 2082 ...