Fixing RRH
The way to fix 2 sector RRH is as follows:
To fix RRH_2 Sector Pole Type (Back to Back Installation)
1
Make sure you have the following items:
Table 16. Parts and Tools for fixing RRH_2 Sector Pole Type (Back to Back Installation)
Category
Description
Parts
M10 × L35 Hex. Bolt (washer assembly,
attached to the unit bracket)
1 EA/RRH
Recommended Torque Value
M10 Hex. Bolt
217 lbf
in
Working Tools
Torque Wrench (100~400 lbf·in)
Torque Wrench Spanner head (apply Hexagon Head: 17 mm)
Spanner (17 mm)
2
Hang the unit bracket hook of RRH-0 side on the mounting bracket_front
hook’s groove and fix it using fasteners.
Figure 49.
Fixing RRH_2 Sector Pole Type (Back to Back Installation 1)
M10 Hex. Bolt
(washer assembly)
Unit Bracket Hook
Mounting Bracket_Front
Hook Groove
[RRH-0]
[RRH-0]
1