3-3
SEPUs
A PSU-B can supply up to 56 station devices or Station Equivalent Power Units (SEPUs). A second
PSU can supply up to 64 station devices or SEPUs (for a total of 120 stations). Several interface cards,
other than station cards, consume 48V power and the consumption of these cards is rated in SEPUs.
The table below shows the SEPU rating of all the cards that consume 48V.
Card Type
SEPU Rating
Notes
8BSI 24
16 DLI
16
See note*
8 DLI
16
Each B channel counts as a port*
16 SLI
16
16 MWSLI
16
SVMi-8 / 16
or Cadence
8
8 SLI
8
8 MWSLI
8
4 BRI
8
Each B channel counts as a port
MGI 8
SLI 4
AC15 4
(All other cards have a SEPU rating of 0)
(* Note: The maximum SEPU rating per system slot is 24. A DS-5012L keyset is rated at 3 SEPUs, so connect-
ing, for example, four of these keysets to a DLI card increases the card’s rating from 16 to 24.)
Cards are also allocated priority ratings from 1 to 4 (1 being the highest). If a higher priority card is
added to a system which is already operating to its maximum power supply capacity (e.g. 56 SEPUs),
lower priority cards will lose an appropriate number of SEPUs in order to allocate them to the new card.
In this case, to ensure that all cards are operating to their maximum SEPU rating, a second power
supply (PSU-60) should be installed.
When the system is operational, you can determine which PSU is supplying each card—or whether a
card is turned on or off—using MMC 806,
Card Pre-install
. The program will indicate which cabinet
and slot a card is installed in, if the card is turned off (P:N)*, or if it is supplied by the PSU-B (P:1) or by
the PSU-60 (P:2). It will also indicate how many card ports are being serviced: e.g. P:2[08] indicates
eight ports are serviced.
(* Note: The display P:N may also indicate that the card has a SEPU rating of 0 or that the PSU is faulty.)
Summary of Contents for OfficeServ500
Page 1: ...SAMSUNG OfficeServ Installation Guide EnterpriseIPSolutions ...
Page 16: ...FIGURES 2 1 TO 2 4 ...
Page 18: ...MOUNTING SCREWS FRONT LEFT SIDE BOTTOM FIGURE 2 2 ATTACHING LEGS TO MAIN CABINET ...
Page 20: ...Mounting Screw Holes Mounting Screw Holes FIGURE 2 4 SECURING CABINET IN RACK ...
Page 25: ...FIGURES 3 1 TO 3 4 ...
Page 27: ...FIGURE 2 4 Power Input Location FIGURE 3 2 POWER INPUT LOCATION ...
Page 28: ...110 220V selection switch FIGURE 3 3 SETTING VOLTAGE ON PSU ...
Page 43: ...FIGURES 4 1 TO 4 24 ...
Page 48: ...P1 P3 U7 U4 U6 U11 U3 P2 U2 U8 U5 U9 U10 U11 FIGURE 4 5 ESM BOARD ...
Page 49: ...Screw Locations FIGURE 4 6 MCP2 LCP2 CARD SCREW LOCATIONS ...
Page 50: ...P1 P2 P3 P4 U1 U2 U4 U4 U13 D3 D4 D2 D1 K2 K1 K3 T3 T4 T2 T1 FIGURE 4 7 MISC BOARD ...
Page 51: ...Screw Locations FIGURE 4 8 SCP2 CARD SCREW LOCATIONS ...
Page 52: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 U8 FIGURE 4 9 SCM BOARD ...
Page 53: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 FIGURE 4 10 MFM BOARD ...
Page 54: ...P2 U3 U4 P1 U1 U8 U5 U9 U2 FIGURE 4 11 RCM BOARD ...
Page 55: ...U10 U9 U8 U5 U7 L1 L2 P1 P2 FIGURE 4 12 MODEM BOARD ...
Page 60: ...EJECTOR TABS SCREWS FIGURE 4 17 TEPRI CARD SCREW LOCATIONS ...
Page 64: ...FIGURE 4 21 SVMi 16 CARD SERIAL PORT RESET BUTTON VOICE PROCESSING MODULE DISK DRIVE ...
Page 67: ...RAM ROM ROM ROM ROM RAM Clear J2 1F DSP JP1 A law u law FIGURE 4 24 VDIAL CARD ...
Page 71: ...110 FUSES VOLTAGE SETTING FIGURE 5 1 FUSES ON PSU ...
Page 74: ...FIGURES 6 1 TO 6 6 ...
Page 75: ...FIGURE 6 1 MDF CONNECTIONS LOOP START LINE TO TRUNK B CARD ...
Page 77: ...FIGURE 6 3 MDF CONNECTIONS AC15 CARD ...
Page 78: ...FIGURE 6 4 MDF CONNECTIONS OFF PREMISES EXTENSION FROM SLI CARD ...
Page 86: ...FIGURES 7 1 TO 7 8 ...
Page 87: ...FIGURE 7 1a MDF CONNECTIONS DIGITAL KEYSET TO DLI CARD ...
Page 88: ...FIGURE 7 1b MDF CONNECTIONS DIGITAL KEYSET TO 16DLI CARD ...
Page 91: ...FIGURE 7 4 WALL MOUNTING A DCS EURO KEYSET ...
Page 92: ...1 2 1 3 FIGURE 7 5 WALL MOUNTING AN iDCS SERIES KEYSET WITH BASE WEDGE ...
Page 93: ...FIGURE 7 6a MDF CONNECTIONS ADD ON MODULE TO DLI CARD ...
Page 94: ...FIGURE 7 6b MDF CONNECTIONS ADD ON MODULE TO 16DLI CARD ...
Page 95: ...FIGURE 7 7a MDF CONNECTIONS SINGLE LINE TELEPHONE TO SLI CARD ...
Page 96: ...FIGURE 7 7b MDF CONNECTIONS SINGLE LINE TELEPHONE TO 8SLI OR 8MWSLI CARD ...
Page 97: ...FIGURE 7 7c MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16SLI CARD ...
Page 98: ...FIGURE 7 7d MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16MWSLI CARD ...
Page 99: ...FIGURE 7 8a MDF CONNECTIONS DOOR PHONE AND DPIM TO DLI CARD ...
Page 100: ...FIGURE 7 8b MDF CONNECTIONS DOOR PHONE AND DPIM TO 16DLI CARD ...
Page 104: ...FIGURES 8 1 TO 8 6 ...
Page 115: ...FIGURES 9 1 TO 9 2 ...
Page 117: ...FIGURE 9 2 CONNECTING iDCS 28D AND 18D KEYSET DAUGHTERBOARDS ...
Page 132: ...Samsung Telecoms U K Limited Brookside Business Park Greengate Middleton Manchester M24 1GS ...