2-3
1. Mount the legs or castors on the main cabinet that is to be the floor mounted (base) cabinet (
2. Prepare both of the cabinets by removing the side and front covers of both prior to installation to
avoid damaging the covers and to allow access to the interior. Remove the top cover from the base
cabinet and the bottom and rear panels from the upper cabinet.
3. Place the upper cabinet on top of the base cabinet ensuring that the upper cabinet locating bumps
are snug in the base cabinet locating dimples. Install the two provided screws in the dimples in the
front lower panel of the upper cabinet and the two provided screws in the dimples in the rear lower
panel of the upper cabinet.
4. Replace the rear panel on the upper cabinet.
5. Proceed with the installation of the power supply unit(s), grounding, power connections, control
cards, interface cards and optional equipment as described in the following chapters.
When a power supply is installed, verify that the power switch is in the proper voltage setting,
110V or 220V as required. (See
Three Cabinet Installation - Floor Mount
One cabinet is to act as the main key service unit (KSU), the others as expansion cabinets.
Check that each cabinet carton includes the following items:
y
OfficeServ500 cabinet
y
Top cover
y
Left and right side covers
y
Front cover
y
Cabinet leg mounting kit
y
AC power and DC power cables
Check that all additional hardware and software is available for installation.
y
Floor mounting equipment (legs or castors).
y
Cards required to make the system functional (i.e., power supply, central processor, station and
trunk cards)
1. Mount the legs or castors on the cabinet that is to be the floor mounted (base) cabinet (
2. Prepare all of the cabinets by removing the side and front covers of each cabinet prior to installation
to avoid damaging the covers and to allow access to the interior. Remove the top cover from the
base and centre cabinets, and the base and rear panels from the centre and upper cabinets.
3. Place the centre cabinet on top of the base cabinet ensuring that the centre cabinet locating bumps
are snug in the base cabinet locating dimples. Install two of the provided screws in the dimples in
the front lower panel of the centre cabinet and the other two provided screws in the dimples in the
rear lower panel of the centre cabinet. Replace the rear panel of the centre cabinet.
Summary of Contents for OfficeServ500
Page 1: ...SAMSUNG OfficeServ Installation Guide EnterpriseIPSolutions ...
Page 16: ...FIGURES 2 1 TO 2 4 ...
Page 18: ...MOUNTING SCREWS FRONT LEFT SIDE BOTTOM FIGURE 2 2 ATTACHING LEGS TO MAIN CABINET ...
Page 20: ...Mounting Screw Holes Mounting Screw Holes FIGURE 2 4 SECURING CABINET IN RACK ...
Page 25: ...FIGURES 3 1 TO 3 4 ...
Page 27: ...FIGURE 2 4 Power Input Location FIGURE 3 2 POWER INPUT LOCATION ...
Page 28: ...110 220V selection switch FIGURE 3 3 SETTING VOLTAGE ON PSU ...
Page 43: ...FIGURES 4 1 TO 4 24 ...
Page 48: ...P1 P3 U7 U4 U6 U11 U3 P2 U2 U8 U5 U9 U10 U11 FIGURE 4 5 ESM BOARD ...
Page 49: ...Screw Locations FIGURE 4 6 MCP2 LCP2 CARD SCREW LOCATIONS ...
Page 50: ...P1 P2 P3 P4 U1 U2 U4 U4 U13 D3 D4 D2 D1 K2 K1 K3 T3 T4 T2 T1 FIGURE 4 7 MISC BOARD ...
Page 51: ...Screw Locations FIGURE 4 8 SCP2 CARD SCREW LOCATIONS ...
Page 52: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 U8 FIGURE 4 9 SCM BOARD ...
Page 53: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 FIGURE 4 10 MFM BOARD ...
Page 54: ...P2 U3 U4 P1 U1 U8 U5 U9 U2 FIGURE 4 11 RCM BOARD ...
Page 55: ...U10 U9 U8 U5 U7 L1 L2 P1 P2 FIGURE 4 12 MODEM BOARD ...
Page 60: ...EJECTOR TABS SCREWS FIGURE 4 17 TEPRI CARD SCREW LOCATIONS ...
Page 64: ...FIGURE 4 21 SVMi 16 CARD SERIAL PORT RESET BUTTON VOICE PROCESSING MODULE DISK DRIVE ...
Page 67: ...RAM ROM ROM ROM ROM RAM Clear J2 1F DSP JP1 A law u law FIGURE 4 24 VDIAL CARD ...
Page 71: ...110 FUSES VOLTAGE SETTING FIGURE 5 1 FUSES ON PSU ...
Page 74: ...FIGURES 6 1 TO 6 6 ...
Page 75: ...FIGURE 6 1 MDF CONNECTIONS LOOP START LINE TO TRUNK B CARD ...
Page 77: ...FIGURE 6 3 MDF CONNECTIONS AC15 CARD ...
Page 78: ...FIGURE 6 4 MDF CONNECTIONS OFF PREMISES EXTENSION FROM SLI CARD ...
Page 86: ...FIGURES 7 1 TO 7 8 ...
Page 87: ...FIGURE 7 1a MDF CONNECTIONS DIGITAL KEYSET TO DLI CARD ...
Page 88: ...FIGURE 7 1b MDF CONNECTIONS DIGITAL KEYSET TO 16DLI CARD ...
Page 91: ...FIGURE 7 4 WALL MOUNTING A DCS EURO KEYSET ...
Page 92: ...1 2 1 3 FIGURE 7 5 WALL MOUNTING AN iDCS SERIES KEYSET WITH BASE WEDGE ...
Page 93: ...FIGURE 7 6a MDF CONNECTIONS ADD ON MODULE TO DLI CARD ...
Page 94: ...FIGURE 7 6b MDF CONNECTIONS ADD ON MODULE TO 16DLI CARD ...
Page 95: ...FIGURE 7 7a MDF CONNECTIONS SINGLE LINE TELEPHONE TO SLI CARD ...
Page 96: ...FIGURE 7 7b MDF CONNECTIONS SINGLE LINE TELEPHONE TO 8SLI OR 8MWSLI CARD ...
Page 97: ...FIGURE 7 7c MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16SLI CARD ...
Page 98: ...FIGURE 7 7d MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16MWSLI CARD ...
Page 99: ...FIGURE 7 8a MDF CONNECTIONS DOOR PHONE AND DPIM TO DLI CARD ...
Page 100: ...FIGURE 7 8b MDF CONNECTIONS DOOR PHONE AND DPIM TO 16DLI CARD ...
Page 104: ...FIGURES 8 1 TO 8 6 ...
Page 115: ...FIGURES 9 1 TO 9 2 ...
Page 117: ...FIGURE 9 2 CONNECTING iDCS 28D AND 18D KEYSET DAUGHTERBOARDS ...
Page 132: ...Samsung Telecoms U K Limited Brookside Business Park Greengate Middleton Manchester M24 1GS ...