2-3
MAIN CONTROL PROCESSOR (MCP2) DAUGHTERBOARD CAPABILITIES
Position
Type of Daughterboard Allowed
LOC1
MFM, SCM, RCM2 and ESM*
LOC2
MFM, SCM, RCM2
LOC3
MFM, SCM, RCM2 and MISC
* The ESM must be installed in this position in a multiple cabinet system or a single cabinet system
running ‘L’ version software.
.
NOTE: Only one of any given type of daughterboard may be installed on any one MCP2
card (e.g. only one MFM can be installed on one MCP2).
Switch Control Processor Card (SCP2)
The Switch Control Processor (SCP2) card is required when an ‘L’ system is to be expanded
beyond a single cabinet, or where a single cabinet system is running ‘L’ version software. It is
installed in slot 9 of the KSU and reduces the available universal card slots to eight. The card
has positions for three daughterboards (refer to the table below).
The first daughterboard position (LOC1)
can support an MFM, an SCM or an RCM2.
The second daughterboard position (LOC2)
can support an MFM, an SCM, an RCM2 or a
MISC.
The third daughterboard position (LOC3)
can support an MFM, an SCM or an RCM2.
SWITCH CONTROL PROCESSOR (SCP2) DAUGHTERBOARDS
Position
Type of Daughterboard Allowed
LOC1
MFM, SCM, or RCM2
LOC2
MFM, SCM, RCM2, or MISC
LOC3
MFM, SCM, or RCM2
NOTE:
1. Only one of any given type of daughterboard may be installed on any one SCP2 card
(e.g. only one MFM can be installed on one SCP2).
2.
The SCP2 contains 4MB of DRAM.