- 33/36 -
Step 1
① If E-27 error is displayed, check that the Temp.
Sensor is connected properly.
Step 2
① Measure temperature Sensor resistance value–
( normal - at room temp : ~1080Ω )
Step 3
① If E-28 error is displayed, and E-28 still
displays after disconnecting the connector,
assume PBA short and replace the PBA.
If E-27 error is displayed after disconnecting
the connector, assume Sensor short and
replace the Sensor.
Check Point
“Temperature Sensor” assembly and component inspection.
Tip 7-2. Temperature Sensor Open(E-27), Short(E-28) Check