- 28/36 -
Step 1
① Check if the Breaker Spec is appropriate for product use (Allowable
Current >20A).
② Check if the Extension cord is appropriate for product use (Allowable
Current > 20A).
Step 2
① Check that the Power cord terminal insulation resistance is normal.
→ Ground and Live, Neutral resistances should be >10㏁.
② Disassemble the unit and check the Wire insulation condition.
③ If any damage to the Wire is found, tape and repair the wire, re-assemble
the unit, and check for proper operation.
Check Point
“Wire harness coating condition inspection.
Tip 6-5. Circuit Breaker Inspection