- 18/36 -
Step 1
① Check if power comes on.
② Check if the gas supply valve is opened completely.
③ Check the Temp. Sensor connection.
Step 2
① Check the Temp. Sensor resistance value (normal : ~1080Ω at room temp.)
(Short : ~0Ω, Open : ~∞Ω)
② Check the PCB Wire connection (if not connected, E27 error will occur.
Must be connected)
Check Point
“Temp. Sensor connection and resistance value” inspection.
Tip 2-2. Temperature Sensor Inspection
Return to
Oven Heating