- 30/36 -
Step 1
① Check if Keys operating properly.
Step 2
① Check if the Membrane ribbon cable is properly connected.
② If issue persists after reconnecting the ribbon cable, inspect the
Membrane ribbon cable.
③ If issue persists after Membrane replacement, replace the Assy PCB and
check for proper operation.
Check Point
“Key operating conditions inspection.
Tip 6-7. Membrane Key Operation Inspection