16
1
Specifications
*1) Mode
HP : Heat Pump, HR : Heat Recovery
*2) Norminal cooling capacities are based on;
Indoor temperature : 26.7°C DB, 19.4°C WB(80°F DB, 67°F WB)
Outdoor temperature : 35°C DB, 23.9°C WB(90°F DB, 75°F WB), Equivalent refrigerant piping : 7.6m(25ft) , Level differences : 0m(0ft)
*3) Norminal heating capacities are based on;
Indoor temperature : 21.1°C DB, 15.6°C WB(70°F DB, 60°F WB)
Outdoor temperature : 8.3°C DB, 6.1°C WB(47°F DB, 43°F WB), Equivalent refrigerant piping : 7.6m(25ft) , Level differences : 0m(0ft)
*4) Sound level was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications are subject to change without prior notice for product improvement.
Type
Model Name
RVXVHT200FE
RVXVHT225FE
Model
Basic
RVXVHT075FE
RVXVHT100FE
2
1
RVXVHT125FE
1
Power Supply
Ø/ V/ Hz
3/ 208~230/ 60
3/ 208~230/ 60
Mode
1)
-
Heat Pump
Heat Pump
Performance
US Ton
TON
16
18
Horse Power
HP
20.0
22.5
Nominal
Capacity
Cooling
2)
Btu/h
192,000
216,000
US RT
16.0
18.0
Heating
3)
Btu/h
216,000
243,000
US RT
18.0
20.3
Power
Nominal Input
Cooling
kW
15.0
18.2
Heating
14.2
17.2
Nominal Running
Current
Cooling
A
57.8
65.7
Heating
49.8
57.9
Circuit Breaker (MCCB/ELB/ELCB)
A
50 + 50
50 + 60
COP
Cooling
-
3.75
3.48
Cooling (US Only)
Btu/Wh
12.80
11.87
Heating
-
4.47
4.15
Compressor
Model
ZPJ72*
ZPJ83*
ZPI61*
ZPI83*
ZPJ72*
ZPJ83*
ZPI61*
ZPI83*
Type
-
DVI Scroll
FVI Scroll
DVI Scroll
FVI Scroll
Number
EA
2
2
1
1
1
1
Piston Displacement
cc/Rev
67.1
58.1
67.1
77.2
58.1
77.2
in³/Rev
4.095
3.545
4.095
4.711
3.545
4.711
Output
kW
6.94
5.83
6.94
7.91
5.83
7.91
Lubricant
Type
-
3MAF POE
3MAF POE
Charging
cc
1,685
1,685
1,685
1,685
1,685
1,685
fl. oz.
57
57
57
57
57
57
Fan
Type / Control
-
Propeller/BLDC
Propeller/BLDC
Motor Output
W
(630) x 2
(630) x 2
Airflow Rate
m
3
/min
(170) x 2
(170) x 1 + (180) x 1
CFM
(6004) x 2
(6004) x 1 + (6357) x 1
External Static
Pressure
Max.
Pa
78.5
78.5
WG
0.315
0.315
Safety
Devices
Mechanical Type
-
High Pressure Switch
High Pressure Switch
-
Comp./Accum. Crank Case Heater
Comp./Accum. Crank Case Heater
-
Fuse for PCB
Fuse for PCB
Electronic Type
-
Over-voltage Protection
Over-voltage Protection
-
Current Transformer
Current Transformer
-
Fan motor Voltage Protection
Fan motor Voltage Protection
Piping
Connections
Liquid
Ø, mm
15.88
15.88
Ø, inch
5/8
5/8
Gas
Ø, mm
28.58
28.58
Ø, inch
1 1/8
1 1/8
Oil (Flare)
Ø, mm
6.35
6.35
Ø, inch
1/4
1/4
Installation
Limitation
Max. Length
m
200
200
ft
656
656
Max. Height
m
50 (40)
50 (40)
ft
164 (131)
164 (131)
Refrigerant
Type
-
R410A
R410A
Factory Charging
kg
(7.5) x 2
(7.5) x 1 + (9) x 1
lbs
(16.53) x 2
(16.53) x 1 + (19.84) x 1
Sound
4)
Sound Pressure
dB(A)
61
62
Set Size
Net Weight
kg
(240) x 2
(240) x 1 + (280) x 1
lbs
(529) x 2
(529) x 1 + (617) x 1
Shipping Weight
kg
(253) x 2
(253) x 1 + (297) x 1
lbs
(558) x 2
(558) x 1 + (655) x 1
Net Dimensions (WxHxD)
mm
(880 x 1668 x 765) x 2
(880 x 1668 x 765) x 1 + (1200 x 1668 x 765) x 1
inch
(34 5/8 x 65 5/8 x 30 1/8) x 2
(34 5/8 x 65 5/8 x 30 1/8) x 1 +
(47 1/4 x 65 5/8 x 30 1/8) x 1
Shipping Dimensions (WxHxD)
mm
(948 x 1888 x 832) x 2
(948 x 1888 x 832) x 1 + (1268 x 1888 x 832) x 1
inch
(37 3/8 x 74 3/8 x 32 3/4) x 2
(37 3/8 x 74 3/8 x 32 3/4) x 1 +
(49 7/8 x 74 3/8 x 32 3/4) x 1
Cable
Main Power (Below 50m)
AWG #
Separate electrical connection for each outdoor units Separate electrical connection for each outdoor units
Communication
AWG #
AWG 16~18
AWG 16~18
Operating
Temp. Range
Cooling
°C
-5~46.1
-5~46.1
°F
23~115
23~115
Heating
°C
-20~24
-20~24
°F
-4~75
-4~75
Summary of Contents for DVM PLUS III
Page 1: ...Outdoor Units SAMSUNG DVM Air Conditioner DVM PLUS III 2010 North America for 60Hz...
Page 2: ......
Page 3: ...Outdoor Units...
Page 6: ...4 DVM PLUS III...
Page 7: ...5 Products I Products 1 Outdoor units 6 2 Indoor units 9 3 Accessories 11...
Page 62: ...DVM DVM Technical Data Book...
Page 63: ......