14_
setting up
select the location where the purifi er is to
install. (Model with the purifi er)
-
If you wish to reassemble the water inlet
and outlet sides of the purifi er during purifi er
installation, see the reference illustration.
-
Cut the water line attached to the purifi er to the
appropriate place after measuring the distance
between the purifi er and the cold water tap.
Replacement Instructions
1. Shut off water supply.
2. Note the Flow direction on the fi lter.
3. Insert water supply tube into the inlet side of the
fi lter until the tube stop.
4. After inserting tube, put together the clip
strongly. The Clip fi x the tube.
5. Turn on the water and check for leaks. If leaks
occur, repeat step 1,2,3,4. If leaks persist,
discontinue use and call your supporting dealer.
6. Flush fi lter for 5 minutes before use.
Remove any residual matter inside the
purifi er. (Model with the purifi er)
-
Open the main water tap to check whether
water is running through the water tube on the
water inlet side of the purifi er.
-
If water does not come out through the line,
check whether the tap is open.
-
Leave the tap open until clean water is running
out and any residual matter that built up during
manufacturing has been removed.
Attach the purifi er lock-clip.
-
Hold the purifi er
lock-clip in the
appropriate
position (under the
sink for example)
and fi x it tightly
into place where to
screw.
Secure the purifi er in position.
-
Fix the purifi er
in position, as
shown in the
fi gure on the
right.
WARRANTY INFORMATION
This water line installation is not covered by the refrigerator
or ice maker manufacturer’s warranty.
Follow these instructions carefully to minimise the risk of
expensive water damage.
Note:
If the coupler does not fi t on the current tap, go the
nearest authorised service dealer and purchase the right
couplers fi ttings.
COUPLER “A”
COUPLER “A”
TAP
TAP
COUPLER
COUPLER
SIDE OF
SIDE OF
PURIFIER
PURIFIER
WATER INLET
WATER INLET
SIDE OF PURIFIER
SIDE OF PURIFIER
LINE OUTLET
LINE OUTLET
90 degree
90 degree
PURIFIER WATER
PURIFIER WATER
CAUTION
Locking Clip
Locking Clip
Insert Locking Clip After
Insert Locking Clip After
tube seated
tube seated
WATER SUPPLY
WATER SUPPLY
INLET SIDE
INLET SIDE
PERMEAT
PERMEAT
FLOW DIRECTION
FLOW DIRECTION
Note :
You must also ensure that
the cut is square and not at any
sort of angle as this could cause a
leak
WATER LINE
WATER LINE
PURIFIER
PURIFIER
WATER
WATER
OUTLET SIDE OF
OUTLET SIDE OF
PURIFIER
PURIFIER
Purifi er lock-clip
Purifi er lock-clip
WATER TUBE
WATER TUBE
Purifi er lock-clip
Purifi er lock-clip
PURIFIER
PURIFIER
DA99-02291S-02.indb 14
DA99-02291S-02.indb 14
2014. 7. 19.
9:00
2014. 7. 19.
9:00