4-7 Replacement of Fuse
Samsung Electronics
4-3
1. Plug off the power cord.
2. Remove fuse cover and the fuse.
After replacement of fuse the fuse cover must
be reset.
1. Remove the wiring.
2. Remove the lamp attachment screw(1 piece)
and the lamp.
1. Remove the wiring
2. Remove the support-MGT.(Screw 1 piece).
3. Remove the back-panel. (Screw seven piece)
4. Remove the BKT-HVT.(Screw: upper resp.
lower each two)
5. Remove the magnetron attachment
screws(four pieces) and then the magnetron.
6. Thermo switch is removed together with.
Care the high tension voltage when
removing wiring.
4-8 Replacement of Lamp
4-9 Replacement of Magnetron, Thermometal switch
Disassembly and Reassembly
LAMP
LAMP attachment screw
Support MGT
Back Panel
BKT HVT
MAGNETRON
Magnetron
attachment
screws(four pieces)
THERMOMETAL
Fuse cover
FUSE