CONFIDENTIAL
5 Troubleshooting
CA17K*/CA17J*
5-13
5-2 General Troubleshooting
5-2-1 No Picture
LED blinks?
LED is green color?
Check Micom.
Check G2 voltage, high voltage
and R, G, B cathode voltage.
No
No
Yes
Refer to 5-2-2 Shut down.
Yes
5-2-2 Shut Down
Blinking LED’s?
Scan failure?
Check horizontal, vertical deflection
system and check power
supply secondary voltages.
Yes
Yes
Check power supply.
No
Check and replace IC201.
Done.
No
Video failure?
Check Video board.
No
Yes