installing the oven _
7
01 In
S
tall
Ing th
E
o
v
E
n
connEctIng to thE maInS powER Supply
Electrical connections must be made
as per the connection plate fixed
to the back of the appliance by an
electrical fitter who must ensure that the
appliance has been connected up in
accordance with fitting instructions and
local regulations.
Where the appliance is not connected
to the mains electricity supply by a plug, an omni polar cutout device (with a contacts
gap of at least 3 mm) must be fitted on the supply side of the connection to meet safety
requirements.
When power is connected, the electronics of the oven are initialised; this neutralizes
the lighting for a few seconds. The electric cable (H05 RR-F or H05 VV-F, Min.
1.5m, 1.5~2.5mm²) must be long enough for it to be connected to the built-in oven
standing on the floor in front of its unit.
Open the back cover) and completely unscrew the connection screw and the cable clamp
before fitting conducting wires into the appropriate terminals.
The earth wire must be connected to the ( ) terminal of the oven.
If the oven is connected to the power supply by a plug, this must remain accessible
once the oven has been fitted.
We cannot accept any liability in the event of an accident resulting from non-existent or
faulty earthing.
Live
Neutral
Earth
min. 5
BF62 SERIES_XEO_EN.indb 7
2011-04-13 7:40:15
Summary of Contents for BF62 Series
Page 39: ...notatki BF62 SERIES_XEO_00269U PO indb 39 2011 04 13 7 59 33 ...
Page 79: ...jegyzetek BF62 SERIES_XEO_00269U HU indb 39 2011 04 13 7 54 49 ...
Page 119: ...Poznámka BF62 SERIES_XEO_00269U SLK indb 39 2011 04 13 8 04 29 ...
Page 159: ...poznámka BF62 SERIES_XEO_CZ indb 39 2011 04 13 7 46 26 ...
Page 199: ...note BF62 SERIES_XEO_EN indb 39 2011 04 13 7 40 27 ...