27
Wall
<20mm
Plastic
Anchor
Fixing the installation plate
2. Fix the indoor unit.
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
(1) Determine the positions of the wooden uprights to be
attached to the window frame.
(2) Attach the wooden uprights to the window frame giving
attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using
tapping screws.
(1)
(2) Fix the plate hanger on two studs.
•
If you mount the plate to a concrete wall using plastic anchors, make sure that
gaps between the wall and the plate, created by projected anchor, is less than
20mm.
•
Search for other spots if there are less than two studs, or the distance between the studs are
from the
plate hanger.
• Fix
the installation plate without inclining to one side.
1. Extend the assembly cable if necessary.
•
Do not connect two or more
cables to extend the length.
It may cause
•
Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not
strong enough to withstand the product weight, the unit could fall and cause injury.
Connecting the assembly cable
When you install the unit, make
refrigerant connections and then electrical connections.
Connect the air conditioner to grounding system before performing the electrical connection.
If unit is uninstalled,
disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.
The maximum length of the cable is 15(
09/12
)/30(
18
) meters.
•
Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to
the power supply, it must be incorporated in a wire with a contact opening of ≥3mm.
Model
P
(Outdoor Unit)
(Indoor-Outdoor)
ower cable
Interconnection cable
Type GL
09/12
18
3G, 2.5mm
² H07RN-F
2G, 0.75mm
² H05RN-F
3G, 1.5mm
² H07RN-F
20A
3G, 2.5mm
² H07RN-F
3G, 1.5mm
² H07RN-F
25A
2
F1/F2 Communication
F1/F2 Communication
Power Supply
Power Supply
G, 0.75mm
² H05RN-F
Connecting the cable
If using a multi system, install as described in the installation manual supplied with the outdoor unit.
MAX_XSA_IBIM_DB98-33747A_E.pdf