Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
•
Avoid the
g places to prevent malfunction of the unit
- Where there is machine oil
- Salty environment such as seaside areas
- Other special atmosphere areas
125mm
or more
300mm or more
125mm
or more
600mm
minimum
300mm
minimum
300mm
minimum
600mm
minimum
' L ' meters maximum
total pipe length
Wrap the refrigerant pipes and the drain hose
with the absorbent pad and vinyl tape. Refer to
page 38 for further details.
You can select the direction of
draining
(left or right).
' H ' meters maximum total
pipe height
Model
L
H
15
8
18
09/12
30
15
Make at least one round: It will reduce noise and vibration
'L' m as maximum pipe length
and 3 m as minimum pipe length
(It will reduce noise and vibration)
Choosing the installation location
If using a multi system, install as described in the installation manual supplied with the outdoor unit.