Troubleshooting
Samsung Electronics
5-6
5-2-6 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis)
1) Troubleshooting
procedure
Remove power cord and plug in again approx. 5 Seconds
Is operation lamp blinking?
Check as in the procedure “NO Power
parts”. Refer to page 5-2.
Normal
Replace battery.
LCD is faulty.
Replace button.
Micom is faulty.
Receiver module is faulty.
Q601(C4375Y) or Q602(C1623Y) is faulty.
IR LED(CL-1L5EU) is faulty.
“ “ sound heard from the indoor unit when ON/OFF
button on the remote control unit pushed?
Voltage of battery less than 2.5V (Remote Control Unit)?
LCD display status of REMOCON normal?
Voltage at PIN #30 of Remocon Micom change?
Voltage at collecter of Q601 or Q602 change?
Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)?
Micom (IC04) is faulty.
Transmission display lamp ( ) blinking when
ON/OFF button on the remote control unit pushed?
YES
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
DB98-04444A(1)-1 4/9/02 2:19 PM Page 5-6
Summary of Contents for AQA07C5(6)ME
Page 3: ...Samsung Electronics 1 2 MEMO...
Page 38: ...MEMO 5 13 Samsung Electronics...
Page 47: ...MEMO Samsung Electronics 6 9...
Page 49: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 ASS Y MAIN PCB TOP PATTERN...
Page 51: ...Samsung Electronics 8 3 8 2 ASS Y MAIN PCB DB93 00437A BOTTOM PATTERN...
Page 53: ...MEMO Samsung Electronics 8 5...
Page 54: ...9 1 Samsung Electronics 9 Wiring Diagrams 9 1 Indoor Unit...
Page 56: ...MEMO 9 3 Samsung Electronics...
Page 57: ...Samsung Electronics Samsung Electronics 10 2 10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 58: ...MEMO Samsung Electronics 10 3...
Page 60: ...ELECTRONICS Samsung Electronics Co Ltd Apr 2002 Printed in Korea Code No DB98 04444A 1...