Operating Instructions and Installation
3-5
Samsung Electronics
Cut the piping hole
sloped slightly
3-2-2 Installation diagram of indoor unit and outdoor unit
A
Indoor unit gas leak test check point
Tape vinyl
Piping
Indoor unit
B
Drain hose installation
Cut the piping hole
sloped slightly
Piping (Liquid) 1/4"
Clamper tube
Installation plate
Installation tube
Screw
Vinyl tape
Drain hose
Putty
Piping may be laid to the rear, left,
right or down .
Right
Rear
Down
70mm or mor
e
250mm
or more
200mm or more
Rear
Left
3
1
5
6
7
4
8
9
1
2
3
4
5
6
7
8
9
2
Remote control
“H” metere
s maximum
Remote control holder
7K/9K BTU
Piping(Gas)3/8”
12K BTU
Model
L
H
**7**
15
7
**9**
15
7
**12**
15
7
DB98-04444A(1)-1 4/9/02 2:18 PM Page 3-5
Summary of Contents for AQA07C5(6)ME
Page 3: ...Samsung Electronics 1 2 MEMO...
Page 38: ...MEMO 5 13 Samsung Electronics...
Page 47: ...MEMO Samsung Electronics 6 9...
Page 49: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 ASS Y MAIN PCB TOP PATTERN...
Page 51: ...Samsung Electronics 8 3 8 2 ASS Y MAIN PCB DB93 00437A BOTTOM PATTERN...
Page 53: ...MEMO Samsung Electronics 8 5...
Page 54: ...9 1 Samsung Electronics 9 Wiring Diagrams 9 1 Indoor Unit...
Page 56: ...MEMO 9 3 Samsung Electronics...
Page 57: ...Samsung Electronics Samsung Electronics 10 2 10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 58: ...MEMO Samsung Electronics 10 3...
Page 60: ...ELECTRONICS Samsung Electronics Co Ltd Apr 2002 Printed in Korea Code No DB98 04444A 1...