Operating Instructions and Installation
Samsung Electronics
3-10
3-2-2(g) Refrigerant Refill
• Refill an air-conditioner with refrigerant when refrigerant has been leaked at installing or using.
1. Vacuum system with pump (for new
installation, leakage).
3. Connect the tank to refill with Refrigerant
4. Set the unit to Low pressure checking mode.
* Press the ON/OFF switch for 5 seconds.
* All lamps blink on the indoor unit.
7. Stop operation of the air conditioner.
9. Close the cap of each valve.
2. Turn the 3-way valve clockwise to close,
connect the pressure gauge(low pressure
side) to the service valve, and open the
3-way valve again.
5. Check the pressure indicated by the
pressure gauge(low pressure side).
* Refer to Low pressure graph.
6. Open the refrigerant tank and fill with refrig-
erant until the rated pressure is reached.
* It is recommended not to pour the refriger-
ant in too quickly, but gradually while
operating a pressure valve.
8. Close the 3-way valve, disconnect the
pressure gauge, and open the 3-way valve
again.
R410A
Suspension hook
High
pressure
gauge
Hand
wheel
Finger tight
fittings
Connected to
high pressure
side
Vacuum
pump
For mounting
other end of
hose when
not in use
Compound
gauge
DB98-04444A(1)-1 4/9/02 2:19 PM Page 3-10
Summary of Contents for AQA07C5(6)ME
Page 3: ...Samsung Electronics 1 2 MEMO...
Page 38: ...MEMO 5 13 Samsung Electronics...
Page 47: ...MEMO Samsung Electronics 6 9...
Page 49: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 ASS Y MAIN PCB TOP PATTERN...
Page 51: ...Samsung Electronics 8 3 8 2 ASS Y MAIN PCB DB93 00437A BOTTOM PATTERN...
Page 53: ...MEMO Samsung Electronics 8 5...
Page 54: ...9 1 Samsung Electronics 9 Wiring Diagrams 9 1 Indoor Unit...
Page 56: ...MEMO 9 3 Samsung Electronics...
Page 57: ...Samsung Electronics Samsung Electronics 10 2 10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 58: ...MEMO Samsung Electronics 10 3...
Page 60: ...ELECTRONICS Samsung Electronics Co Ltd Apr 2002 Printed in Korea Code No DB98 04444A 1...