MAINTENANCE
91
English
A
Model(s) : AG056KSVANH
B
Air-to-water heat pump : yes
C
Water-to-water heat pump : no
D
Brine-to-water heat pump : no
E
Low-temperature heat pump : no
F
Equipped with a supplementary heater : no
G
Heat pump combination heater : no
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump,
parameters shall be declared for low-temperature application.
I
Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(
*)
Prated
(o)
35
kW
P
Seasonal space heating energy
efficiency
η
s
131
%
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature Tj
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
Tj = -7 °C
Pdh
28.5
kW
-
Tj = -7 °C
COPd
(S)
1.71 -
Tj = +2 °C
Pdh
20.2
kW
Tj = +2 °C
COPd
(S)
2.92 -
Tj = +7 °C
Pdh
12.3
kW
Tj = +7 °C
COPd
(S)
5.66 -
Tj = +12 °C
Pdh
8.3
kW
Tj = +12 °C
COPd
(S)
5.87 -
T
Tj = bivalent temperature
Pdh
34.8
kW
T
Tj = bivalent temperature
COPd
(S)
2.37 -
U
Tj = operation limit temperature
Pdh
34.8
kW
U
Tj = operation limit temperature
COPd or
PERd
(S)
2.37 -
V
For air-to-water heat pumps
Tj = -15 °C (if TOL < -20 °C)
Pdh
-
kW
V
For air-to-water heat pumps
Tj = -15 °C (if TOL < -20 °C)
COPd or
PERd
(S)
-
- or %
W
Bivalent temperature
Tbiv
-10
°C
X
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Y
Cycling interval capacity for
heating
Pcych
-
kW
Z
Cycling interval efficiency
COPcyc or
PERcyc
(AA)
-
- or %
AB
Degradation co-efficient
(**)
Cdh
0.9
-
AC
Heating water operating limit
temperature
WTOL
-
°C
AD
Power consumption in modes other than active mode
AE
Supplementary heater
AF
Off mode
P
OFF
0.040
kW
N
Rated heat output
(*)
Psup
-
kW
AG
Thermostat-off mode
P
TO
0.040
kW
AJ
Type of energy input
AH
Standby mode
P
SB
0.040
kW
AI
Crankcase heater mode
P
CK
0.140
kW
AK
Other items
AK
Other items
AL
Capacity control
variable
(AM)
AN
For air-to-water heat pumps :
Rated air flow rate, outdoors
-
21840
m
3
/h
(AO)
AP
Sound power level, indoors/
outdoors
L
WA
-/83
dB
AR
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
-
-
m
3
/h
(AO)
AQ
Emissions of nitrogen oxides
NOx
-
mg/kWh
AS
For heat pump combination heater
AS
For heat pump combination heater
AT
Declared load profile
-
AU
Water heating energy efficiency
η
wh
-
%
AV
Daily electricity comsumption
Q
elec
-
kWh
AW
Daily fuel consumption
Q
fuel
-
kWh
AX
Contact details
Http://www.samsung.com
AY
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output
of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
AZ
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
BA
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BB
2)
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email to: [email protected]
Summary of Contents for AG042KSVANH