Setting key function
60
English
K4 (number of
press)
Display contents
Display
SEG1
SEG2, 3, 4
19 times
EVI outlet temperature
J
-42 °C
-, 4, 2
20 times
Main EEV 1 step
K
2000 steps
2, 0, 0
21 times
Main EEV 2 step
L
2000 steps
2, 0, 0
22 times
EVI EEV step
M
300 steps
3, 0, 0
23 times
H/R EEV step
N
300 steps
3, 0, 0
24 times
Fan step (SSR or BLDC)
0
13 steps
0, 1, 3
25 times
Current frequency (Compressor 1)
P
120 Hz
1, 2, 0
26 times
Current frequency (Compressor 2)
Q
120 Hz
1, 2, 0
27 times
Suction 2 temperature
R
-42 °C
-, 4, 2
28 times
Master indoor unit address
S
Master indoor unit not selected
BLANK, N, D
If indoor unit No.1 is selected as the
master unit
0, 0, 1
29 times
Snow accumulation sensor voltage
T
1.80 V
1, 8, 0
30 times
Total suction temperature
U
-42 °C
-, 4, 2
K4 (number of
press)
(Press and hold
the K4 for 3
seconds to enter
the setting)
Display contents
Display
Page1
Page2
1 time
Main version
MAIN
Version (ex.: 1412)
2 times
Hub version
HUB
Version (ex.: 1412)
3 times
Inverter compressor 1 check
INV1
Version (ex.: 1412)
4 times
Inverter compressor 2 check
INV2
Version (ex.: 1412)
5 times
Fan 1 check
FAN1
Version (ex.: 1412)
6 times
Fan 2 check
FAN2
Version (ex.: 1412)
7 times
EEP version
EEP
Version (ex.: 1412)
8 times
Automatically assigned address of the units
AUTO
Seg1
Seg2
Seg3, 4
Hydro
controller:
A
Hydro
controller: 0
Address
(ex.: 07)
9 times
Manually assigned address of the units
MANU
Seg1
Seg2
Seg3, 4
Hydro
controller:
A
Hydro
controller: 0
Address
(ex.: 15)