Required tools

General tools

 Vacuum pump

 Torque wrench

 Pipe cutter

 Reamer

 Pipe bender

 Spirit level

 Screw driver

 Spanner

 Drill

 L wrench

 Measuring tape

Tools for test operations

 Thermometer

 Resistance meter

 Electroscope

Choosing the installation location

Indoor unit

f

f

Install the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the 
outdoor unit.

 - It is effective to install the unit at the place where air flow is not blocked and the cool air can be distributed throughout 

the room. 

f

f

Install the unit at a place where there is no obstacle against the wind around the air intake and air outlet.

f

f

Avoid a place near the door which is frequently used by people.

f

f

Avoid a place exposed to direct sunlight. (If it is unavoidable, install a sunshade).

 - Surface of the product may get discolored.

Install it on even ground.
•  Make sure there is no abnormal operation or noise generation.
•  If installed on uneven ground, water may overflow.

Outdoor unit

f

f

Avoid a place exposed to direct sunlight. (If it is unavoidable, install a sunshade).

f

f

A place free from the risk of combustible gas leakage.

f

f

A place which can bear the weight of the unit.

f

f

A place which can bear the fixing strength of the outdoor unit.

f

f

Avoid a place exposed to oil (including machine oil)

f

f

Avoid a saline place.

f

f

Avoid a place exposed to sulfide gas (hot spring zone). 

 - When installing the unit at such special environmental conditions, it may cause trouble to the product. When it is 

unavoidable, special maintenance is required.

f

f

A place where discharged air and noise of the outdoor unit does not disturb the neighborhood.

 - Take extra care not to cause any inconvenience to your neighbors when installing the unit on the borderline with your 

neighborhood.

f

f

A place where strong wind does not head against the air outlet of the outdoor unit.

 - If a strong wind heads directly against the air outlet at the time of cool operation, a safety device can be operated.

Do not install the outdoor unit on a unstable places (such as rooftop). If installation is unavoidable, make sure that you 
fixed the unit firmly. Avoid places where strong wind or storm can possibly knock down the product (such as seashore or 
place with frequent storm)

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd   37

2014-03-12   오전 9:33:10

Summary of Contents for AF**FSSDA Series

Page 1: ...678 www samsung com pk support TUNISIA 80 1000 12 www samsung com n_africa support JORDAN 0800 22273 06 5777444 www samsung com Levant support English SYRIA 18252273 www samsung com Levant support English MOROCCO 080 100 2255 www samsung com n_africa support SAUDI ARABIA 920021230 www samsung com sa support www samsung com sa_en support English TURKEY 444 77 11 www samsung com tr support INDIA 180...

Page 2: ...F FSZDA Series Air Conditioner user installation manual imagine the possibilities Thank you for purchasing this Samsung product DB68 03892A 5 EN ES FR AR 칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A 5 indd 55 2014 03 12 오전 9 33 19 ...

Page 3: ...ctronicEquipment Applicableincountrieswithseparatecollectionsystems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please sepa...

Page 4: ... 28 Troubleshooting 31 Open Source Announcement 34 Safety precautions 35 Required tools 37 Choosing the installation location 37 Indoor outdoor unit installation diagram 38 Accessories 41 Drilling a hole and fixing the indoor unit 42 Connecting pipes 42 Connecting drain hose 45 Electrical work 46 Vacuum pump 50 Performing leak test 51 Installing the earth wire 52 Charging refrigerant 52 Check and ...

Page 5: ...er at the circuit breaker Do NOT disassemble FOR INSTALLATION WARNING Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line f fExtending the power line may result in electric shock or fire f fDo not use an electric transformer It may result in electric shock or fire f fIf the voltage frequen...

Page 6: ...ult in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line f fFailure to do so may result in electric shock fire an explosion or other problems with the product f fMake sure to use a socket outlet with ground FOR INSTALLATION CAUTION Install your appliance on a level and hard floor that can support ...

Page 7: ... death or property damage FOR POWER SUPPLY WARNING When the circuit breaker is damaged contact your nearest service center Do not pull or excessively bend the power line Do not twist or tie the power line Do not hook the power line over a metal object place a heavy object on the power line insert the power line between objects or push the power line into the space behind the appliance f fThis may ...

Page 8: ...ially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not operate the appliance with wet hands f fThis may result in electric shock Do not strike or pull the air conditioner with excessive force f fThis may result in fire injury or problems with the...

Page 9: ...t your finger into the air conditioner f fThis may result in electric shock or burns Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people f fSince this may be dangerous due to a lack of oxygen open a window at least once an hour If any foreign substance such as water has entered the appliance cut off the power supply and contact the nearest s...

Page 10: ...ter from the air conditioner f fThe water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product f fThis may result in burns or injury Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes f fThis may res...

Page 11: ...ectric shock or fire FOR CLEANING CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges f fTo avoid cutting your fingers wear thick cotton gloves when cleaning it Do not clean the inside of the air conditioner by yourself f fFor cleaning inside the appliance contact your nearest service center f fWhen cleaning the internal filter refer to th...

Page 12: ...and windows f fWhen the air conditioner is used with open doors and windows cooling effect will decrease f fIf you use the air conditioner for over an hour open the window to ventilate the air about once every hour Install the product away from sunlight or heating devices f fClose the curtain when the sun shines f fDo not use any heating devices during cooling operation Cooling effect will decreas...

Page 13: ...ice may activate and stop the operation Mode Indoor temperature Outdoor temperature Indoor humidity Cool 21 C 32 C 21 C 52 C Relative humidity 80 or less Dry 21 C 30 C 21 C 52 C Heat 0 C 30 C 10 C 24 C If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed When the outdoor temperature goes down to 10 C the heating capacity may decrease to 60...

Page 14: ...e installation condition Pipe length over standard of 5m installation place and insulation etc is different heating capacity may decrease even though the air conditioner performs normally In this case use extra heating apparatus Heating capacity 100 of rated capacity 80 of rated capacity 10 C 7 C 24 C Outdoor temperature 칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A 5 indd 13 2014 03 12 오전 9 32 57 ...

Page 15: ...e automatically when turning on the air condtioner Support bracket Control panel Front remote controller holder Fix the remote controller holder on the front side of an indoor unit with screws Air control panel Move with selected air direction Air outlet Discharge cool air Lighting Lighting is turned on or off Virus doctor If the support bracket is excessively impacted it may become damaged CAUTIO...

Page 16: ...ure Outdoor unit operation Mute Virus doctor Fan speed Defrost indicator Timer Buttons on control panel On Off button Individual control button Temperature control button Increase or decrease the temperature by 1 C The number of air outlets is different depending on the models 칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A 5 indd 15 2014 03 12 오전 9 32 59 ...

Page 17: ...f When pressing the button first the mode of air conditioner will change to cool mode f f You can adjust the desired temperature by 1 C within the range of 18 C 30 C by pressing the buttons 3 Adjust fan height with the three individual air outlet control buttons f f You can adjust the fan height by controlling the air outlet individually f f Individual contol will be canceled when turning the air ...

Page 18: ...ows through the air conditioner with the 4 different fan speeds Air Flow Set the air flow to cool effectively according to the surrounding Solo Family Select Solo Family mode Turbo Operate in maximum fan speed to cool warm quickly OffTimer Set the Off timer on Remote controller display Beep Off To silence the beep sound when pressing the button Set Cancel Set Cancel the timer good sleep mode OnTim...

Page 19: ... the remote controller and store it Lighting WPS Wi Fi Make sure that water is not allowed to enter the remote controller CAUTION There is a possibility that the air conditioner will not operate by remote controller near strong light such as a fluorescent lamp or neon sign In this case use the remote controller in front of the remote controller receiver of the indoor unit If other electrical produ...

Page 20: ...r temperature may decrease Purity This operation eliminates harmful contaminants within the air to provide a healthy and clean environment f f You can select Purity mode by pressing the button while the air conditioner is on or off f f In purity mode will appear on the display of an indoor unit and will appear in 1 minute f f You can press the button during Cool Dry mode and adjust the desired tem...

Page 21: ...to set the desired fan speed Auto Auto Operation mode will change to Cool mode when the Fan speed is adjusted Cool Auto Low Medium High Dry Auto Purity Low Medium High Heat Auto Low Medium High Press the button to adjust the desired temperature Auto Operation mode will change to Cool mode when desired temperature is adjusted Cool You can adjust the desired temperature by 1 C within the range of 18...

Page 22: ...w direction according to the surrounding environment Press the button to select desired air flow direction WPS Wi Fi Indirect Air will not flow to the person directly but provide coolness rather indirectly Direct Cool warm air will flow directly to the person Center Cool warm air will come out intensively from the center Wide Air flow blades will move left right to provide the cool heat air to wid...

Page 23: ...hours f f Default operation hour is set to 8 hours 3 Press the Set Cancel button to activate it f f Off timer indicator stops blinking and set time will be displayed f f icon appears in the display of the indoor unit and good sleep mode starts operating f f If you don t press the Set Cancel button to start the good sleep mode within 10 seconds the operation is canceled so you should check the Off ...

Page 24: ...perature is too low you may feel cold or dry and catch a cold You may not have such a restful sleep if the good sleep is set too short or long because the default is set to 8 hour operation If the good sleep mode is set less than 4 hours the operation will stop after the set hours If the good sleep mode is set over 5 hours it will run asWake up stage from the last one hour before it stops automati...

Page 25: ... the air conditioner will return to the previous status so you should check the On Off timer indicator on the remote controller display or icon on the indoor unit display Cancel Press the Set Cancel button once again Additional options available in On timer mode You can select from Auto Cool Dry Purity Heat You can adjust the temperature in Auto Dry Heat mode Operation mode will change to Cool mod...

Page 26: ...ly Preset time on On timer is longer than Off timer Ex On timer 3 hours Off timer 1 hour The air conditioner will be turned off after 1 hour from the moment you have set the timer After 2 hours your air conditioner will turn on On timer and Off timer setting time should be different from each other If you press Set Cancel button or Power button while the both On timer and Off timer are set simulta...

Page 27: ... caused by devices such asTV fan etc NOTE Lighting function You can create fresh mood of indoor room with soft light by turning the light on After pressing the button and checking the indicator on the remote controller display press the Lighting button to adjust the lighting level of an indoor unit Lighting Remote controller display f f Each time you press the Lighting button during air conditione...

Page 28: ...quiet mode the quiet mode will be canceled NOTE Auto clean operation Auto clean function will prevent mold from growing by eliminating the moisture inside of the indoor unit Press the button Lighting When the air conditioner is turned on f f icon appears in the display of the indoor unit and the Auto cleaning function will run for 3 minutes after air conditioner stops operating When the air condit...

Page 29: ...Dust off the cloth before cleaning to prevent indoor unit from being scratched by the foreign material on the cloth If it is difficult to clean the indoor unit heat exchanger on your own contact service center NOTE Do not clean the display using alkaline detergent Do not clean the surface with sulfuric acid hydrochloric acid or organic solvents thinner kerosene acetone or attach stickers It may da...

Page 30: ...ter push the Zero filter Dry the filter completely in the shade f f When drying the Full HD filter make sure the filter is not exposed to direct sunlight Remove dust with a vacuum cleaner or running water f f When the dust is serious clean the filter with warm water which contains a neutral detergent However when rubbing out the filter with a brush the Full HD filter may be damaged CleantheFullHDf...

Page 31: ...not disassemble the Zero filter when cleaning it f f If the accumulated dust is heavy soak the filter in water mixed with detergent and shake it in water for 30 minutes until it is cleaned Dry the filter in a ventilated area f f Put the filters vertically for 12 24 hours when drying Drying time can be shorter depending on the condition f f Do not dry the Zero filter in direct sunlight It may get d...

Page 32: ... to set the temperature lower in Cool mode higher in Heat mode than the current temperature Check if the Full HD Filter is blocked by dirt If there is a lot of dust on the Full HD Filter cooling heating performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away If you want to operate the air condi...

Page 33: ...oduct point the remote controller towards the remote control receiver and press the button Timer function does not work Check if you have pressed the Set Cancel button on the remote controller after setting the time The air conditionerisnot turned off Check the air conditioner is in auto cleaning mode When turning the air conditioner off after using the auto cleaning function it will take 3 minute...

Page 34: ... service center Noise is generated Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Cracking sound may ocuur during the operation of the air conditioner push the Zero filter to the end Steam is generated from the outdoor unit When the air conditioner is in heat mode in the winter steam may generate during the frost removing...

Page 35: ...g com It is also possible to obtain the complete corresponding source code in a physical medium such as a CD ROM a minimal charge will be required The following URL http opensource samsung com opensource Memory seq 0 leads to the download page of the source code made available and open source license information as related to this product This offer is valid to anyone in receipt of this informatio...

Page 36: ...ps there is potential risk of fire or electric shock due to dust or water f f Make sure to use the part provided or specified parts for the installation work The use of defective parts could cause an injury or leakage of water due to a fire an electric shock the unit falling etc f f Make sure that the refrigerant gas does not leak after completing the installation If the refrigerant gas comes into...

Page 37: ...f Wear thick gloves during the installation process If not personal injury may occur due to the air conditioner parts f f Be careful not to touch the outdoor unit inlet or aluminium pins You may get personal injury f f Do not install the outdoor unit in a place where animals could live If an animal comes into contact with the electric parts damage or fire may occur In addition ask the customer to ...

Page 38: ...unavoidable install a sunshade f f A place free from the risk of combustible gas leakage f f A place which can bear the weight of the unit f f A place which can bear the fixing strength of the outdoor unit f f Avoid a place exposed to oil including machine oil f f Avoid a saline place f f Avoid a place exposed to sulfide gas hot spring zone When installing the unit at such special environmental co...

Page 39: ... minimize the piping length but make sure it is over 5m f f Select the installation location where you can keep the piping bending to maximum 10 spots f f Stated cooling performance is based on product with 5m piping Installation space for floor type indoor unit f f To minimize the waste of space due to installation install the indoor unit as shown in below figure Top view After completing the ins...

Page 40: ... or more Fixing outdoor unit Follow below method to firmly fix the outdoor unit f f Using rubber leg Put the rubber leg to the outdoor unit leg Refer to illustration on the right f f Using anchor bolt On a flat rigid ground use 4 anchor bolt M10 to fix the unit Anchor bolt should be purchased separately Select the anchor bolt that is long enough to securely fix the outdoor unit Anchor bolt fixing ...

Page 41: ...ake sure to check for proper drainage in defrost operation Do not install on the place where bottom part of the outdoor unit is at lower level than the drain hose When installing the drain hose for draining the outdoor unit condensation of the cooling heating product make sure to install it so that it allows natural draining When fixing the product make sure that the product is level When the prod...

Page 42: ... leg Main power cable Indoor outdoor unit communication cable Indoor Outdoor unit power cable Drain plug Installation accessories Drain connection hose Connection pipe Insulation Φ6 35mm Connection pipe Insulation Φ15 88mm Sleeve Service tube Cable tie Putty Bushing Finishing tape Drain insulation tube Installation accessories may differ depending on the model 칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A 5 i...

Page 43: ... make sure there is no leakage When recovering the refrigerant stop the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury WARNING Installation procedure 1 Slight...

Page 44: ...unit and tightening by applying appropriate torque f f Flare process 1 Cut the pipe using the pipe cutter Oblique Rough Burr 90 2 Remove burr on the edge of the pipe If burr is not removed after cutting the pipe there is a risk of refrigerant gas leakage If foreign substance such as burr goes into the pipe there is a risk of product breakdown Therefore face the pipe downward when doing the work Pi...

Page 45: ...ure to perform leak test Refer to Performing leak test on page 51 6 Insulate the drain hose after connecting it Insulate it correctly to avoid dew formation f f Pipe insulation 1 Insulate the refrigerant pipes heavily with the finishing tape If the insulation is poor dew may form and leak through the indoor 2 Use finishing tape wind up the refrigerant pipe 3 When you bend the pipe and secure a min...

Page 46: ...xtension is unavoidable due to its short length use silicone sealant to securely seal the connection to prevent leakage Do not use the insulation tape CAUTION Duct drainage Polypropylene PP Drain hose Insulation foamed polyethylene Connection drain hose Connect the drain hose through the upper hole for drain hose Upper hole for a drain hose Piping Drain hose 410 mm Hole for piping connection Conne...

Page 47: ... f Make sure to connect earth wire Type Indoor unit Indoor power Indoor outdoor unit power cable Outdoor unit Outdoor power Earth leakage circuit breaker Power 1Ph 220 240V 50 60Hz Circuit breaker 20A Indoor outdoor unit power cable 1 0mm2 or more Outdoor unit power cable 2 5mm2 or more Indoor outdoor unit communication cable 0 75mm2 or more Connecting procedure 1 After loosening the 4 screws of s...

Page 48: ...rd Installed back to front Compressed part is cut Ring terminal is detached f f After tightening there should be no gap between a terminal and a screw If there is a gap fire may occur due to the heat of electronic connection part A screw is not tightened firmly or there is a gap between a screw and ring terminal Terminal is tightened back to front When connecting the cables to the outdoor unit rev...

Page 49: ...leeve from both sides Connection sleeve After peeling off the tube wire you must insert a contraction tube CAUTION f f Method 2 Twist the wire cores together and push it in to the sleeve Connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of ...

Page 50: ...on work is completed wrap it with the insulation tape to finish Insulation tape In case of extending the electric wire please DO NOT use a round shaped pressing socket Incomplete wire connections can cause electric shock or a fire CAUTION 칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A 5 indd 49 2014 03 12 오전 9 33 17 ...

Page 51: ...onger 4 After degree of vacuum has been established open the service valve as shown in the illustration Use soapsuds to check for refrigerant leakage on the connection part of the pipes 2 1 F T Condenser Outdoor unit Air flow Sensor EEV Compressor Indoor unit heat exchanger ServiceValve ServiceValve f f Vacuuming air conditioner Executevacuumpumponthemanifoldgaugeconnectedtolowpressureside topurge...

Page 52: ...eck for any possible leakage insert inert gas into the pipes connected to indoor outdoor units and check the connection part of the indoor outdoor units with soap lather or liquid for leakage test Tightening torque for charging port cap Refer to the table Tightening torque for body cap Refer to the table R 22 Diameter of the screw 7 16 20UNF R 410A Diameter of the screw 1 2 20UNF Charging core Spi...

Page 53: ...ngth If the installed pipe length exceeds standard length 5m you must add 30g of refrigerant R 410A for every 1m You do not need to charge the additional refrigerant when pipe length is less than 5m Gas side Liquid side Manifold gauge Electronic scale Refrigerant 3 After charging the refrigerant disconnect the manifold gauge from the service port and close the service cap 4 Deactivate the refriger...

Page 54: ...rature written down previously it is operating normally 7 When checking above step 1 6 is done tell the user how to use the air conditioner Pumpdownprocedure Whenremovingtheproduct 1 Press the Power button on the indoor unit control panel for 5 seconds to enter the Pump down mode and operate the compressor for over 5 minutes Or Press the Set Cancel Mode and Temp button on the remote controller sim...

Reviews: