39
EN
G
LIS
H
Outdoor unit
30
cm
or
mo
re
50cm or
more
Air guide
(Not provided by
manufacturer )
30cm or more
20cm or more
60cm
or m
ore
30cm
or more
Outdoor
unit leg
Rubber leg
Spare space for piping
Installation space for outdoor unit
Refer to following examples for wind protection.
f
f
When installing in the street with lots of buildings, install the product parallel to the street.
f
f
In the places with strong wind, install the product with air outlet facing the wall.
Strong wind
Rooftop
Air
outlet
Wall
The air intake faces towards the wall
30cm or more
30cm or more
50cm or
more
Spare space
for piping
The air outlet faces towards the all
30cm or more
60cm or more
50cm or
more
Spare space
for piping
60cm or
more
Fixing outdoor unit
Follow below method to firmly fix the outdoor unit.
f
f
Using rubber leg
- Put the rubber leg to the outdoor unit leg. (Refer to illustration on the right.)
f
f
Using anchor bolt
- On a flat, rigid ground, use 4 anchor bolt (M10) to fix the unit. (Anchor bolt should be
purchased separately.)
- Select the anchor bolt that is long enough to securely fix the outdoor unit.
Anchor bolt fixing dimension
33
8m
m
660mm
❋
❋
If you need to ensure the outdoor unit from falling, use wires to fix it firmly.
• Loosen the 4 screws from the top cover of the outdoor unit.
• Put the wire around the screws and fasten the screws.
• Fix the wire on the ground.
• When the outdoor unit is not firmly fixed, it may fall and cause personal injury or property damage.
• When the outdoor unit is installed in water-proofed rooftop, fix the wire on the wall.
CAUTION