46
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR SPACE HEATER
II)
A
Model(s) : AE090JXYDEH
B
Air-to-water heat pump : yes
C
Water-to-water heat pump : no
D
Brine-to-water heat pump : no
E
Low-temperature heat pump : no
F
Equipped with a supplementary heater : no
G
Heat pump combination heater : no
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump,
parameters shall be declared for low-temperature application.
I
Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output(
*)
Prated
(o)
6
kW
P
Seasonal space heating energy
efficiency
η
s
126
%
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
-
Tj = -7 °C
Pdh
5.5
kW
-
Tj = -7 °C
COPd
(S)
1.89
-
Tj = +2 °C
Pdh
3.3
kW
Tj = +2 °C
COPd
(S)
3.01
-
Tj = +7 °C
Pdh
2.1
kW
Tj = +7 °C
COPd
(S)
4.25
-
Tj = +12 °C
Pdh
1.0
kW
Tj = +12 °C
COPd
(S)
6.78
-
T
Tj = bivalent temperature
Pdh
6.2
kW
T
Tj = bivalent temperature
COPd
(S)
1.77
-
U
Tj = operation limit temperature
Pdh
6.2
kW
U
Tj = operation limit temperature
COPd
(S)
1.77
-
V
For air-to-water heat pumps
Tj = -15 °C (if TOL < -20 °C)
Pdh
-
kW
V
For air-to-water heat pumps
Tj = -15 °C (if TOL < -20 °C)
COPd
(S)
-
-
W
Bivalent temperature
Tbiv
-10
°C
X
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Y
Cycling interval capacity for heating
Pcych
-
kW
Z
Cycling interval efficiency
COPcyc
(AA)
-
-
AB
Degradation co-efficient(
**)
Cdh
0.9
-
AC
Heating water operating limit
temperature
WTOL
-
°C
AD
Power consumption in modes other than active mode
AE
Supplementary heater
AF
Off mode
P
OFF
0.080
kW
N
Rated heat output(
*)
Psup
-
kW
AG
Thermostat-off mode
P
TO
0.011
kW
AJ
Type of energy input
AH
Standby mode
P
SB
0.011
kW
AI
Crankcase heater mode
P
CK
0.000
kW
AK
Other items
AK
Other items
AL
Capacity control
variable
(AM)
AN
For air-to-water heat pumps :
Rated air flow rate, outdoors
-
53
m
3
/h
(AO)
AP
Sound power level, indoors/
outdoors
L
WA
-/63
dB
AR
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
-
-
m
3
/h
(AO)
AQ
Emissions of nitrogen oxides
NOx
-
mg/kWh
AS
For heat pump combination heater
AS
For heat pump combination heater
AT
Declared load profile
-
AU
Water heating energy efficiency
η
wh
-
%
AV
Daily electricity comsumption
Q
elec
-
kWh
AW
Daily fuel consumption
Q
fuel
-
kWh
AX
Contact details
http://www.samsung.com
AY
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a
supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
AZ
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
BA
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BB
2)
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email to: [email protected]
EHS MONO_ODU_IM_05387A-01_BOOK.indb 46
2015-06-25 오후 4:40:25