SAMLEX AMERICA INC. | 95
SECTION 4 |
Parameter Setup
4.8 GROUP 5 PARAMETER SET UP: OTHER FUNCTIONS
4.8.1 Programming Ranges and Default / Factory Preset Values of Parameters under Group 5 -
OTHER FUNCTION
Table 4.9 gives details of programming ranges and default values of parameters under Group 5 - OTHER FUNCTION.
Refer to Fig 4.4 under Section 4.1.3.3 for Menu Map for navigating through the various parameters under this Group.
TABLE 4.9 Group 5 Parameter Set Up: OTHER FUNCTION
(Refer to Menu Map at Fig 4.4, Section 4.1.3.3)
Parameter
Setup Screen
Nos. for
EVO-1212F/
1212F-HW/
1224F/
1224F-HW
(Column 1)
Parameter
Setup Screen
Nos. for:
• EVO-2212/ 3012/
2224/ 4024
• EVO-2212E/
3012E/ 2224E/
4024E
• EVO-4248SP
(Column 2)
Parameter
(Column 3)
Setting range
EVO-1212F
EVO-1212F-HW
(Column 4)
EVO-2212
EVO-2212E
(Column 5)
EVO-3012
EVO-3012E
(Column 6)
EVO-1224F
EVO-1224F-HW
(Column 7)
EVO-2224
EVO-2224E
(Column 8)
EVO-4024
EVO-4024E
(Column 9)
EVO-
4248SP
(Column 10)
1
1
POWER SAVING
0 = Disable ; 1 = Enable
(
Default:
0 = Disable)
2
2
ENTER POINT
4 - 50W
(
Default:
6W)
4 - 50W
(
Default:
6W)
4 - 50W
(
Default:
8W)
4 - 50W
(
Default:
6W)
4 - 50W
(
Default:
6W)
4 - 50W
(
Default:
8W)
4 - 50W
(
Default:
8W)
3
3
WAKE UP
POINT
5 - 50W
(
Default:
7W)
5 - 50W
(
Default:
7W)
5 - 50W
(
Default:
10W)
5 - 50W
(
Default:
7W)
5 - 50W
(
Default:
7W)
5 - 50W
(
Default:
10W)
5 - 50W
(
Default:
10W)
4
4
REMOTE
SWITCH
0 = Button Type , 1 = Switch Type
(
Default:
0 = Button Type)
–
(See NOTE 1)
5
RELAY
FUNCTION
0 = Charger / Other
1 = Normal / Fault
2 = Generator 0
3 = Generator 1
4 = Generator 2
(
Default:
2 = Generator 0)
0 = Charger / Other
1 = Normal / Fault
2 = Generator 0
3 = Generator 1
4 = Generator 2
(
Default:
2 = Generator 0)
5
6
COMM ID
1 - 255 (
Default:
1)
6
7
BUZZER
0 = OFF ; 1 = ON (
Default:
1 = ON)
7
8
DISCHARGE
BEEP
0 = OFF ; 1 = ON (
Default:
0 = OFF)
8
9
DEFAULT RESET
0 = No ; 1 = Yes (
Default:
0 = No)
9
10
DATALOG TIME
0 = Disable; 1 = 1 sec; 2 = 10 sec; 3 = 30 sec;
4 = 1 min; 5 = 5 min; 6 = 10 min (
Default:
1 = 1 sec)
10
11
PARAMETER
SAVE
0 = No ; 1 = Yes (
Default:
0 = No)
11
12
TEMP UNIT
0 = °C ; 1 = °F (
Default:
0 = °C)
12
13
PASSWORD
DISABLE
0 = No , 1 = Yes (
Default:
0 = No)
NOTES for Table 4.9:
1. Parameter "RELAY FUNCTION"
(Parameter Setup Screen No. 5 under Columns 2 & 3)
is available only for EVO-2212 / 3012F/
EVO-2224 / 4024 / 4248SP.
Summary of Contents for EVO-RC-PLUS