SAMLEX AMERICA INC. | 107
SECTION 4 |
Parameter Setup
4.8.2.13.1 Programming Steps for Parameter "PASSWORD DISABLE"
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
For programming options, see Table 4.9:
• Screen No.12 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.13 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/
4024/4024E & EVO-4248SP
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O
W
E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A S S
W
O R D D I S A B L E
0 = N o
Down Key x 4 times
Enter Key
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A S S
W
O R D D I S A B L E
0 = N o
ð
Enter Key
4.9 GROUP 6 PARAMETER SET UP: RC-PLUS SETTING
4.9.1 Programming Ranges and Default/ Factory Preset Values of Parameters Under Group 6 –
RC-PLUS SETTING
Table 4.10 below gives details of programming ranges and default values of parameters under Parameter Group 6 -
RC-PLUS SETTING.
Refer to Fig 4.5 under Section 4.1.3.4 for Menu Map for navigating through various parameters
under this Group 6
.
These parameters are used to control dimming of LCD back lighting of Remote Control EVO-RC-PLUS.
Table 4.10 Group 6 Parameter Set Up: RC-PLUS SETTING
(Refer to Menu Map at Fig 4.5, Section 4.1.3.4)
Parameter
Setup Screen
No.
(Column 1)
Parameter
(Column 2)
Setting range
(i) EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(ii) EVO-2212 / 2212E / 3012 / 3012E / 2224 / 2224E / 4024 / 4024E
(iii) EVO-4248SP
(Column 3)
1
ACTIVE LCD LIGHT
0 = 0%, 1 = 25%, 2 = 50%, 3 = 75%, 4 = 100%
(Default: 4 = 100%)
2
IDLE LCD LIGHT
If any key on the Remote
Control EVO-RC-PLUS has not
been pressed for time set by
parameter "IDLE LCD TIMER",
the backlight will dim to the
programmed option
0 = 0%, 1 = 25%, 2 = 50%, 3 = 75%, 4 = 100%
(Default: 1 = 25%)
3
IDLE LCD TIMER
If any key on the Remote
Control EVO-RC-PLUS has not
been pressed for time set by
this parameter, the backlight
will dim to the programmed
option selected through
parameter "IDLE LCD LIGHT"
1 to 60 min.
(Default = 5 min)
(i) Down Key x 11 times for EVO-1212F/1212F-
HW/1224F/1224F-HW
(ii) Down Key x 12 times for EVO-2212/2212E/30
12/3012E/2224/2224E/4024/4024E
& EVO-4248SP
Summary of Contents for EVO-RC-PLUS
Page 127: ...SAMLEX AMERICA INC 127 NOTES ...