SAMLEX AMERICA INC. | 105
SECTION 4 |
Parameter Setup
4.8.2.9.1 Programming Steps for Parameter "DEFAULT RESET"
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
For programming options, see Table 4.9:
• Screen No.8 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.9 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/4024/
4024E & EVO-4248SP
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O
W
E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
B U Z Z E R
1 = O n
Down Key x 4 times
Enter Key
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
B U Z Z E R
1 = O n
ð
Enter Key
4.8.2.10 DATALOG TIME AND DATALOG DISABLE
(Table 4.9, (i) Parameter Setup Screen No. 9 under Column 1 (ii) Parameter Setup Screen No. 10 under Column 2)
Refer to Sections 5.2 to 5.3 on Data Logging.
Data Logging uses external SD Card (
FAT 16/32, up to 32 GB capacity
) to record the values of various Operating
Parameters /Events/Errors with Date and Time stamp controlled by an internal Real Time Clock (
RTC
). Parameters/
Events/Errors are recorded under “Data Logging Fields” (
Section 5.2.2 for information on Data Logging Fields for
various EVO
TM
Models
)
The recorded values of the various Operating Parameters are their “
Average Values
” computed from “Instantaneous
Values” scanned over a programmable “time interval” set by programming parameter “DATALOG TIME”. Events/
Errors are recorded as soon as they are sensed.
Apart from providing 6 options for setting the “time interval” for computing the “
Average Values
”, programming
parameter “DATALOG TIME” is also used to disable Data Logging by selecting programming option “0=Disable”
Programming Options
(i) 0=Disable, (ii) 1=1 sec (Default), (iii) 2=10 sec, (iv) 3=30 sec, (v) 4=60 sec, (vi) 5=5 min, (vii) 6=10 min
4.8.2.10.1 Programming Steps for Parameter "DATALOG TIME"
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
For programming options, see Table 4.9:
• Screen No.9 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.10 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/4
024/4024E & EVO-4248SP
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O
W
E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D A T A L O G
T I M E
1 = 1 s e c
Down Key x 4 times
Enter Key
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D A T A L O G
T I M E
1 = 1 s e c
ð
Enter Key
(i) Down Key x 7 times for EVO-1212F/1212F-
HW/1224F/1224F-HW
(ii) Down Key x 8 times for EVO-2212/2212E/301
2/3012E/2224/2224E/4024/4024E
& EVO-4248SP
(i) Down Key x 8 times for EVO-1212F/1212F-
HW/1224F/1224F-HW
(ii) Down Key x 9 times for EVO-2212/2212E/301
2/3012E/2224/2224E/4024/4024E
& EVO-4248SP