PNEUMATIC HOIST 200
ED. 01 - 10/2019 - Cod. 150097
STOP
UP
DOWN
•
B
roaden centering clamps (
J
4
)and fit the drum 200 liters on
the base plate of the hoist;
•
Turn the two-way valve (
J
1
) downwards by pressing down
the pot near the top edge of the frame. Stop the descent of
the hoist by turning the knob (
J
1
) valve into the intermediate
position;
• Centre correctly the stem so that it is aligned with the pressing
plate;
•
Open the bleed valve (
J
3
) placed on the plate pressing;
• turn the knob (
J
1
) bi-directional valve down letting the pres
-
sure plate in the trunk. Close the bleed valve (
J3
). Secure
centering clamps (
J
4
) at the edges of the frame.
• The two rear terminals once established are no longer remo
-
ved.
• Will remain as a reference for the centring of the blanks later.
•
Open the slide valve (
J7
) on the air regulator toward the pump.
• Using the knob (
J
6
) air regulator increase the pump feeding
pressure to the minimum necessary for the operation of the
same.
During use of the hoist-way valve knob (
J1
)
is usually left to the middle position.
The weight of the equipment will facilitate
the descent of the hoist gradually decrease
the level of the material.
In the presence of very dense knob can be
left turned down so as to compress with
more force the product.
Avoid approaching too much to the hoist
during lifting and lowering.
When you try to check out the pot blowing
from the stem, this could get out of the
shot: pay close attention to your hands and
getting away with the head from moving
parts.
Keep in mind that the hoist is always
pushing. Once the gasket goes into the
stem, blocking plate pressure-pump could
move quickly until you reach the product
surfaces. Pay close attention to your hands
and getting away with the head from mo-
ving parts.
(To increase the pressure, turn the knob (
J
6)
clockwise).
The pump will operate and will stop when the entire room
of the product will be full. The pump will start again to work
whenever you open the delivery valve (or gun).
• If the pump is having difficulty in suction of the spray, slowly
open the bleed valve ( (
J
3
) placed on the plate pressing and
close it as soon as you will get the product from the relief
valve.
Fig. 10
Fig. 11
Fig. 12
J2
J6
J1
J6
J4
J4
J4
J7