background image

www.larius.com

11

PNEUMATIC HOIST 200

ED. 01 - 10/2019  - Cod. 150097

G

H

I

A1

USE CORRECT

   

ATTENTION

 

Make sure there is sufficient space in height when 
the hoist is in the highest position.

During operation of the pump can create conditions 
of electrostatic energy.

• before using the pump you must provide for the 

grounding connection.

• the pump is equipped with a special terminal and 

its grounding wire (A1).

The single column pneumatic extrusion ram is suitable for oper

-

ations with 200-litre drums.

•    The  stem  must  be  correctly  positioned  between  the  two 

columns and securely attached to the base plate using the 
clamps.

•   The stem must not be deformed or damaged.

•   The pumps installed on the hoist are piston and are suitable 

for pumping highly viscous products (

up to 2 million cps

).

•   Use products that are chemically compatible with the pump 

parts that are in contact with the product to be pumped. 
Contact the manufacturer before using products other than 
those provided for in the contract of sale.

•   The pressure of the compressed air supply must be between 

3 ÷ 6 bar.

 

NOTE

Any other use of the equipment not provided for in the contract of sale 

is declared improper.

GROUNDING

SETTING-UP

The operator will have to arrange an environment suitable to the 

plant before installing as indicated here below:

• 

An area wide enough to allow the drum loading an unloading 

and routine maintenance operatiions.

• 

Ensure there is a sufficient space in height to enable the 
ram lifting and an easy access to the air regulation groups.

• 

For the pneumatic ram feeding, use a tube with an internal 

diameter no lower than 10 mm

Install a condensate filter and a shut-off valve 
type ON-OFF on the air supply line to the ram.

• 

Make sure the air governors to the pump and ram are closed 

(

turn counterclockwise the control knob to close them

)

• 

Make sure the air delivery valve to the shovel plate is closed.

• 

Make sure the air delivery pipe to the pneumatic pump is 
connected to the ram and to the pump.

• 

Make sure the air delivery pipe to the shovel plate is connected 

to the ram and to the shovel plate.

WORKING

Check all the fittings for the connection of the 
different components (

pump, flexible hose, 

gun, etc..

) before using the equipment.

Avoid approaching too much to the ram during 
the ascent and descent functions. 

• 

Open the air supply to the ram.

Fig. 8

Summary of Contents for LARIUS PNEUMATIC HOIST 200

Page 1: ...Pneumatic hoist Single mast for 200 litres drums w w w l a r i u s c o m English OPERATING INSTRUCTIONS ED 01 10 2019 Cod 150097...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...ionally FLAT PRESSING EXTRACTION PROCEDURE FROM the STEM for extrusion versions only p 14 REPLACE OF THE DRUM for extrusion versions only p 14 ROUTINE MAINTENANCE p 14 fixing with screw anchors p 15 P...

Page 4: ...www larius com 4 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Page 5: ...ment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has no...

Page 6: ...200 litre drums This system allows for the safe clean transfer of material for use from the storage container directly into the application area This safe reliable system allows empty drums to be repl...

Page 7: ...rting to cavitate with subsequent defusing They are suitable for pumping highly viscous products The follower plate is equipped with a series of special anti oil rubber high strength flat or toroidal...

Page 8: ...inlet with bayonet connection Command unit support bracket Up down drive lever Up down pressure regulator Extrusion ram lifting cylinder Available air outlet Pneumatic pump air delivery Open closeval...

Page 9: ...ations in force in the country where the plant is installed and used Read carefully and entirely the following instructions before using the product Please save these instructions in a safe place The...

Page 10: ...RTHEPROTECTIONOF HEARING IN CASE OF WORK NEAR THE PLANT IF THE PRODUCT TO BE USED IS TOXIC AVOID INHALATION AND CONTACT BY USING PROTECTION GLOVES GOGGLES AND PROPER FACE SHIELDS The conditions of gua...

Page 11: ...mustbebetween 3 6 bar NOTE Any other use of the equipment not provided for in the contract of sale is declared improper GROUNDING SETTING UP The operator will have to arrange an environment suitable t...

Page 12: ...the stem does not present excessive bruising these can cause the pressure plate of the hoist with an automa tically inside the drum Place the drum on the ram s plate Turn the control lever downwards...

Page 13: ...to the middle position The weight of the equipment will facilitate the descent of the hoist gradually decrease the level of the material In the presence of very dense knob can be left turned down so...

Page 14: ...e frame proceed as follows Make sure that the regulator K1 air inlet in the stem is at 0 bar and open the stopcock K2 against the regulator it self Turn the knob K4 upward Slowly increase the air pres...

Page 15: ...ents Holes must be the same size as those in the base plate It is possible to fix the base plate whose existing holes can be used as a guide to drill the floor with precision in a single operation The...

Page 16: ...l of the pump Decrease the feed air pressure to the pump Manuallyresetthepneumaticmotor see the instruction manual of the pump Disassemble the motor and check see the instruction manual of the pump Ac...

Page 17: ...he pump Cleanorreplacethewornparts see theinstructionmanualofthepump Clean Disconnect the outlet product pipe Feed pump at mini mumpressureandcheckifdelivery increases the outlet pipe Increase feed ai...

Page 18: ...9 10 11 12 13 14 15 81010 510429 81083 95158 510003 19186 1 95153 4 6 7 5 8 10 9 Pos Code Description Qty Short terminal Long terminal Handwheel Extrusion ram plate Pneumatic cylinder Guide rod Stirr...

Page 19: ...14 15 16 17 18 19 91102 35560 22027 4004 900662 91026 91020 91107 3348 96259 Air regulator unit Pos Code Description Qty GPA 1 4 Valve Screw TCE M4x22 M4 Nut Silencer 1 4 Elbow 1 4 hose d10 Elbow 1 4...

Page 20: ...2 1 1 2 3 4 5 6 7 8 9 10 11 12 12 12 12 11 13 14 15 16 16 17 18 19 20 23 22 21 24 23 22 21 Pos Code Description Qty Flat gaskets blowing Flat disc pressing 3 8 1 4 reduction Drain hose Snap ring int U...

Page 21: ...www larius com 21 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Page 22: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...