•   The packed parts should be handled as indicated in the symbols 

and markings on the outside of the packing.

•   Before  installing  the  equipment,  ensure  that  the  area  to  be 

used is large enough for such purposes, is properly lit and has 
a clean, smooth floor surface.

•   The user is responsible for the operations of unloading and 

handling and should use the maximum care so as not to damage 
the individual parts or injure anyone.

   To  perform  the  unloading  operation,  use  only  qualified  and 

trained personnel (truck and crane operators, etc.) and also 
suitable hoisting equipment for the weight of the installation 
or its parts. 

   Follow carefully all the safety rules.
   The personnel must be equipped with the necessary safety 

clothing.

•   The  manufacturer  will  not  be  responsible  for  the  unloading 

operations and transport to the workplace of the machine.

•   Check the packing is undamaged on receipt of the equipment. 

Unpack the machine and verify if there has been any damage 
due to transportation.

   In case of damage, call immediately LARIUS and the   Shipping 

Agent. All the notices about possible damage or anomalies must 
arrive timely within 8 days at least from the date of receipt of 
the plant through Registered Letter to the Shipping Agent and 
to LARIUS.

The conditions of guarantee do not apply in the 

following situations:

- improper washing and cleaning of components 

causing malfunction, wear or damage to the 
equipment or any of its parts;

- improper use of the equipment;
- use that does not conform with applicable 

national legislation;

- incorrect or faulty installation;
- modifications, interventions and maintenance that 

have not been authorised by the manufacturer;

- use of non-original spare parts or parts that do 

not correspond to the specific model;

- total or partial non-compliance with the 

instructions provided. 

CONDITIONS OF GUARANTEE

•   THE EMPLOYER SHALL TRAIN ITS EMPLOYEES ABOUT ALL 

THOSE RISKS STEMMING FROM ACCIDENTS, ABOUT THE 
USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND 
ABOUT THE GENERAL RULES FOR ACCIDENT PREVENTION 
IN COMPLIANCE WITH INTERNATIONAL REGULATIONS AND 
WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS 
USED.

•   THE  BEHAVIOUR  OF  THE  EMPLOYEES  SHALL  STRICTLY 

COMPLY WITH THE ACCIDENT PREVENTION AND ALSO 
ENVIRONMENTAL REGULATIONS IN FORCE IN THE COUNTRY 
WHERE THE PLANT IS INSTALLED AND USED.

•   KEEP  YOUR  WORK  PLACE  CLEAN  AND  TIDY.  DISORDER 

WHERE YOU ARE WORKING CREATES A POTENTIAL RISK 
OF ACCIDENTS.

•   ALWAYS  KEEP  PROPER  BALANCE  AVOIDING  UNUSUAL 

STANCE.

•   BEFORE USING THE TOOL, ENSURE THERE ARE NOT DA-

MAGED PARTS AND THE MACHINE CAN WORK PROPERLY.

•   ALWAYS FOLLOW THE INSTRUCTIONS ABOUT SAFETY AND 

THE REGULATIONS IN FORCE. 

 

•   KEEP  THOSE  WHO  ARE  NOT  RESPONSIBLE  FOR  THE 

EQUIPMENT OUT OF THE WORK AREA. 

•   

NEVER

 EXCEED THE MAXIMUM WORKING PRESSURE 

INDICATED. 

•    (IF PROVIDED) 

NEVER

 POINT THE SPRAY GUN AT YOURSEL-

VES OR AT OTHER PEOPLE. THE CONTACT WITH THE CA-
STING CAN CAUSE SERIOUS INJURIES. 

•   IN CASE OF INJURIES CAUSED BY THE GUN CASTING, SEEK 

IMMEDIATE MEDICAL ADVICE SPECIFYING THE TYPE OF 
THE PRODUCT INJECTED. 

NEVER

 UNDERVALUE A WOUND 

CAUSED BY THE INJECTION OF A FLUID. 

•   ALWAYS  DISCONNECT  THE  SUPPLY  AND  RELEASE  THE 

PRESSURE IN THE CIRCUIT BEFORE PERFORMING ANY 
CHECK OR PART REPLACEMENT OF THE EQUIPMENT.

•   NEVER  MODIFY  ANY  PART  IN  THE  EQUIPMENT.  CHECK 

REGULARLY THE COMPONENTS OF THE SYSTEM. 

  REPLACE THE PARTS DAMAGED OR WORN.

SAFETY RULES

The disposal of packaging materials is a customer’s 
competence and must be performed in accordance 
with the regulations in force in the country where 
the plant is installed and used.It is nevertheless 
sound practice to recycle packaging materials in an 
environment-friendly manner as much as possible.

Read carefully and entirely the following instructions 
before using the product. Please save these 
instructions in a safe place.

The unauthorised tampering/replacement of one 
or more parts composing the machine, the use of 
accessories, tools, expendable materials other than 
those recommended by the manufacturer can be a 
danger of accident. 
The manufacturer will be relieved from tort and 
criminal liability. 

TRANSPORT AND UNPACKING

www.larius.com

3

ED. 10 - 07/2020 - Cod. 150133

Pneumatic hoist twin mast for 200 litres

Summary of Contents for LARIUS PNEUMATIC HOIST 200

Page 1: ...w w w l a r i u s c o m OPERATING AND MAINTENANCE MANUAL EN PNEUMATIC HOIST twin mast for 200 litres drums lever control ED 10 07 2020 Manuale Cod 150133...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...OF GUARANTEE 3 SAFETY RULES 3 REFERENCE STANDARDS 5 DANGERS 5 USE CORRECT 6 INSTALLATION 7 PNEUMATIC CONNECTION 9 PRINCIPLE OF OPERATION 10 TECHNICAL DATA 11 DESCRIPTION OF THE EQUIPMENT 12 procedure...

Page 4: ...d prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not been given IF PROVIDED There is a risk of injury or serious lesion r...

Page 5: ...EIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE BEHAVIOUR OF THE EMPLOYEES SHALL STRIC...

Page 6: ...losion If the product to be used is toxic avoid inhalation and contact by using protection gloves goggles and proper face shields Take proper safety measures for the protection of hearing in case of w...

Page 7: ...operation material priming piston and compressed air is supplied to the unit whenever Before performing any maintenance or repair disconnect the compressed air supply and arrange for decompression of...

Page 8: ...when the hoist is in the highest position The drum must not be deformed or damaged The pumps installed on the hoist are piston and are suitable for pumping highly viscous products up to 2 million cps...

Page 9: ...isting holes can be used as a guide to drill the floor with precision in a single operation Thedepthoftheholesdrilledintheconcreteofnoimportance fortheexpansionofthegussetanddoesnotaffecthisestate pro...

Page 10: ...a hose with an internal diameter of not less than 10 mm Make sure that the air regulators A are closed Turn the adjusting knob clockwise to close it Make sure the air hose to the air pump is attached...

Page 11: ...www larius com 9 ED 10 07 2020 Cod 150133 Pneumatic hoist twin mast for 200 litres closed open Air delivery regulator for pump operation Air delivery to the hoist Drain the condensate Valve opening c...

Page 12: ...o ducts as these flow naturally towards the inlet pressure and the suction valve thanks to the plate to plate so that the pump starts to cavitate resulting in bomb disposal The pressure plate has a se...

Page 13: ...Ground fixing 4 expansion bolts Stem type 200 litres Length A 910 mm max 1260 mm Height B 1535 mm closed 2035 mm open 2535 mm with hose Width C 825 mm Pump type NOVA 55 1 OMEGA 28 1 GHIBLI 24 1 VEGA...

Page 14: ...ylinder pressure regulator 5 Supply air pressure plate valve Pos Description 6 Delivery hose for air pump 7 Pump motor 8 Lifting cylinders 9 Air treatment group for pump 10 Product drum DESCRIPTION OF...

Page 15: ...12 Air intake valve for extraction 13 Relief valve Pos Description 14 Product drum locking terminals 15 Holes for hoist securing 16 Purge valve for pump priming 17 Pressing plate www larius com 13 ED...

Page 16: ...owering Carefully follow the directions below to open the pressing plate in the drum Open the air supply M1 Turn the control lever M2 upward Check if there are dents on the drum M5 as these could caus...

Page 17: ...Greasethepressingplategasket M7 andtheinternalsurface of the drum Center the drum M5 correctly on the plate M8 so that it is aligned with the pressing plate M7 Lock the clamps M6 to secure the drum M...

Page 18: ...rum rotate the control lever up Rise the pump and then repeat the operation Never under any circumstances plate hands between the plate and the edge of the drum The pressing plate may suddenly come ou...

Page 19: ...tartthepumpuntiltheproductcomesoutofthedrainvalve N1 Close the valve N1 Clean any product residues that have come out of the valve to avoid damaging the machine Get a can N2 to collect the product lea...

Page 20: ...setothehoistduringascent and descent The pressing plate may suddenly come out when removing it from the drum be carefulofhandsandkeepheadawayfrommoving machine parts Keep in mind that the extrusion ra...

Page 21: ...wards Open the air inlet valve P5 in the drum Gradually increase air pressure on the regulators P2 and P3 up to about 1 bar to raise the hoist Once the pressing plate has been removed the drum can be...

Page 22: ...sence and in the absence of pressure To clean or replace the Insert loosen the screen of the group LUBRIFICATOR For proper lubrication set the lubrication through the screw so as to dispense 1 drop ap...

Page 23: ...nob upwards The pressing plate is locked in the trunk Gradually open the valve for air venting in order to promote the release of the pressure plate from the stem Leaking material from the edges from...

Page 24: ...031 Screw 6 510013 4 Washer Pos Code Description 7 510013 2 Top of the bottom 8 34009 Washer 9 81032 Screw 10 510013 3 Plate fixing sleeve press 11 32024 Washer 5 6 7 2 1 9 11 8 4 3 10 S AUTO PARTS AU...

Page 25: ...at Pos Code Description 7 5359 Attack 90 8 510049 T attack 9 5546 attack 1 4 d 10 mm 10 5356 Reduction M F 11 510104 Pneumatic cylinder 2 1 3 4 5 6 7 7 12 14 13 19 18 17 13 14 7 11 8 9 10 9 10 3 T UPP...

Page 26: ...1 2 M reduction F 4 16 510087 Bed hoist Pos Code Description 17 510036 Short Terminal 18 95153 Washer 19 510037 Knob 20 510003 Screw 7 12 14 13 19 18 17 13 16 14 7 11 8 9 10 9 10 20 10 U SPARE BASE ST...

Page 27: ...ulator 3 4004 Manual valve Pos Code Description 4 95350 96259 FRL air treatment group 5 30532 Double action valve V 1 3 4 5 SPARE AIR GROUP Fig 1V www larius com 25 ED 10 07 2020 Cod 150133 Pneumatic...

Page 28: ...19 18 16 16 15 12 12 11 14 13 17 23 22 21 23 22 21 25 20 1 2 9 10 26 12 11 12 3 8 4 5 6 7 W FLAT DISC PRESSING Fig 1W www larius com 26 ED 10 07 2020 Cod 150133 Pneumatic hoist twin mast for 200 litr...

Page 29: ...d screw for fixing plate 12 95007 Nut M20 13 510059 1 Drain rod sleeve Pos Code Description 14 510053 3 Auction 15 510005 Upper Seal 16 510006 Premianello disk 17 510008 Ring 18 81083 Washer D10 19 85...

Page 30: ...1 Elbow 1 7 95350 96259 The FRL Group 1 pressure gauge 8 95325 Screw M5X70 TCE Pos Code Description 9 510102 Bracket 10 510103 Skid plate 11 32024 Washer D 8 12 510029 Screw TE M8X130 13 5549 1 4 quic...

Page 31: ...alve in the stem Pos Description 7 Air valve pressing plate 8 Intake air regulator pressure plate 9 Hoist air regulator 10 Lifting lowering lever hoist 11 Hoist cylinders 11 11 1 2 3 4 6 9 10 7 8 5 Y...

Page 32: ...I n t e n t i o n a l l y b l a n k p a g e...

Page 33: ...2006 42 Machinery Directive furthermore to the harmonized standards UNI EN ISO 12100 1 2 Machinery safety basic concepts general principles of design Basic terminology methodology Technical principle...

Page 34: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...