6.4.13. Procedure G1: Disassembly of the protective tube assembly (21)
(for
Xcite
®
+ guns)
•
Step 1
:
Unscrew the nut (20.1) by means of the wrench supplied
with the gun.
•
Step 2
:
Remove the screen support (21.1) and the screen (21.2).
•
Step 3
:
Remove the seal (21.3).
•
Step 4
:
Unscrew the fitting (19).
•
Step 5
:
Loosen the screw (21.4) with a 4 mm hex key.
•
Step 6
:
Unscrew the fluid tube (21.5).
•
Step 7
:
Check the condition of the parts as well as the seal (21.3).
Change them if necessary.
20.1
21.3
21.5
21.1
21.2
19
21.4
21.3