SAMES KREMLIN
Page 13
Manual : 573.199.112
CONTROL BOX :
SAMES KREMLIN
STAINS FRANCE
Name and address of the manufacturer
CE
II (2) G [EEx ia] IIA
CE
: European conformity
:
For use in explosive area
II
: group II
(2)
: Control box contains components ensuring the safety of the class 2
fluid module.
G
: Gas
[EEx ia]
: Control box contains SI ia barriers.
IIA :
Gas group for the equipment category
Tension
PU 3000 voltage
P air
Maximum air pressure
P prod
Maximum fluid pressure
Serie / Serial
Number given by SAMES KREMLIN. The two first numbers indicate the
manufacturing year.
Ref
Part number of the PU 3000
Phase
Single phase
Fréquence
50-60Hz / Mains frequency
Ampérage
Maximum current used
NE PAS DEBRANCHER
SOUS TENSION
DO NOT DISCONNECT
WHILE POWER ON
-
Environmental Indication
(refer to § 2 - Environment)
FLUID MODULE :
SAMES KREMLIN
STAINS FRANCE
Name and address of the manufacturer
CE
II 2 G IIA T3
CE
: European conformity
:
For use in explosive area
II
: group II
2
: class 2
Surface equipment meant to area where explosive atmospheres due to
gas, vapours, mists are liable to appear from time to time in usual operating
G
: gas
IIA :
Gas group for the equipment category
T3
: Maximum surface temperature : 200°C / 392°F
P air
Maximum air pressure
P prod
Maximum fluid pressure
Serie / Serial
Number given by SAMES KREMLIN. The two first numbers indicate the
manufacturing year.
Ref
Part number of the PU 3000
NE PAS DEBRANCHER
SOUS TENSION
DO NOT DISCONNECT
WHILE POWER ON
-
Summary of Contents for PU3000 4L 30/1
Page 63: ...SAMES KREMLIN Page 51 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model Airless...
Page 68: ...SAMES KREMLIN Page 56 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 30 1...
Page 73: ...SAMES KREMLIN Page 61 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 53 1...
Page 79: ...SAMES KREMLIN Page 67 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L Flowmax 53 1...