SAMES KREMLIN
Page 24
Manual : 573.199.112
Parameters
Description
Factory adjustment
Your
adjustments
Alarm volume for the B pump
Minimum value : 1 L
Maximum value : 40 000 L
0 : parameter not taken into account
OK : reset of low level pump shut off –B-
0
Initialization mode (values of the high and low
thresholds of the movement sensors)
OK : to activate that mode
Flushing time
Minimum value : 10 seconds
Maximum value : 500 seconds
120 s
Flushing volume
Minimum value : 10 cc
Maximum value : 5000 cc
500 cc
Number of thousands of cycles before
preventive maintenance on the A pump
Minimum value : 1
Maximum value : 9999
500 cyc
(i.e. 500 000 cycles)
Number of thousands of cycles before
preventive maintenance on the B pump
Minimum value : 1
Maximum value : 9999
500 cyc
(i.e. 500 000 cycles)
Percentage of dry extract in the base
Minimum value : 0 %
Maximum value : 100 %
50 %
Ratio Test mode
OK
: to activate that mode
Summary of Contents for PU3000 4L 30/1
Page 63: ...SAMES KREMLIN Page 51 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model Airless...
Page 68: ...SAMES KREMLIN Page 56 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 30 1...
Page 73: ...SAMES KREMLIN Page 61 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 53 1...
Page 79: ...SAMES KREMLIN Page 67 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L Flowmax 53 1...