5. Maintenance
WARNING : Before any intervention on the powder coating booth, it is imperative to switch off
the electrical and pneumatic power supplies.
5.1. Maintenance summary table
The periodicity of maintenance indicated in the procedures below is only indicative and
depends on the nature of the powder used. The user will have to create his own maintenance
range as he uses
SAMES KREMLIN
equipment.
5.2. Cleaning
WARNING : All cleaning operations should only be carried out using compressed air or the
cleaning product recommended by
SAMES KREMLIN
.
It is strictly forbidden to use a flammable product whose flash point is lower than the ambient
temperature plus 5°C to clean the booth (as the booth lining is made of PVC, there is a risk of
accumulation of electrostatic charges that can cause a spark and ignite the solvent).
Do not spray any cleaning agent into the booth with the ventilation system running.
Refer to the safety rules (
) before any intervention.
5.2.1. Procedure
A1
: Booth interior cleaning
Depending on the condition, we recommend cleaning the interior of the booth once or twice
a year using PS 1098 (Ref.: 100000037) recommended by
SAMES KREMLIN
.
Follow the procedures described below:
Procedure
Detail
Duration
Frequency
Cleaning
A
A1
Booth interior cleaning
Between 2
and 4 hours
depending on
the height and
condition of
the booth.
1 to 2 times a
year
A2
Booth exterior cleaning
Between 2
and 4 hours
depending on
the height and
condition of
the booth.
1 time per
year
A3
Check the proper operation of the suction
shutters
2 min
Every 3
months