background image

SAMES KREMLIN 

- 3 - 

N° :  578.001.130-UK-1804 

 

 

CAUTION! 

It is forbidden to use material containing high concentrations of halogenated hydrocarbon 

solvents with  

aluminium

  or 

zinc fillers 

.Non-compliance with the instructions may cause 

explosion risk causing serious or fatal injury. 

EQUIPMENT REQUIREMENTS 

 

Guards (motor cover, coupling shields, connectors,…) have been designed for 

a safe use of the equipment. 

The manufacturer will not be held responsible for bodily injury or failure 

and / or property damage due to destruction, the overshadowing or the 

partial or total removal of the guards. 

 

PUMP

 

 

 

Before carrying out any work, it is imperative to read and clearly understand the disassembly and 

reassembly instructions before servicing. The operator must understand the equipment and the 

safety instructions. These instructions are available in the equipment manuals. 
The air motor is designed to be mounted with a pump. Never modify any components or 

couplings. When operating, please keep hands away from moving parts. Before starting up the 

equipment, please read the PRESSURE RELIEF instructions. Please ensure that any relief or 

drain valves fitted are in good working order. 

 

HOSES

 

 

  Keep hoses out of circulation areas, moving parts or hot surfaces, 

  Never expose product hoses to temperature higher than + 60°C / 140° F or lower than 0°C 

/ 32° F, 

  Never pull or use the hoses to move the equipment, 

  Tighten all fittings as well as the hoses before operating the equipment, 

  Check the hoses regularly; change them if they are damaged, 

  Never exceed the maximum working pressure (MWP) indicated on the hose. 

USED PRODUCTS

 

 

Considering the wide variety of products that are available and  can be used in our equipment it is  

impossible to check and make recommendations for  all chemical data,regarding the risks of 

possible chemical attack and  their long term chemical reaction 
SAMES KREMLIN can not be held liable for :  

  compatibility of wetted parts, 

  risks to staff and the surroundings,  

  for worn or defective parts, for faulty equipment or units, or the qualitiy of final product. 

It is the responsibility of the user to know and prevent any possible risks such as toxic vapours, 

fires or explosions. He shall determine the risks of immediate reactions or pursuant to repeated 

exposures of the staff, 
SAMES KREMLIN shall not be liable for physical  injuries, direct or indirect material damages 

caused by the use of chemicals. 

Summary of Contents for AIRMIX 10C50 GT

Page 1: ...TANT Before assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIG...

Page 2: ...la best mmelser F rs kra er om att anv ndare av denna utrustning erh llit utbildning till fullo f rst tt s kerhetsf reskrifterna och till mpar dem K yt n turvallisuuden varmistamiseksi velvollisuutesi...

Page 3: ...mai jos POMPE INTENSIVE TM BASSE ET MOYENNE PRESSION POUR APPLICATION PNEUMATIQUE ET AIRMIX A MOTEUR AVEC INVERSEUR INTENSIVE TM AIRMIX LOW PRESSURE PUMP AIR MOTOR WITH REVERSING BLOCK INTENSIVE AIRMI...

Page 4: ...nta Toto prohl en o skod se vyd v na v hradn odpov dnost v robce Za izdajo te izjave o skladnosti je odgovoren izklju no proizvajalec Toto vyhl senie o zhode sa vyd va na vlastn zodpovednos v robcu Ez...

Page 5: ...sembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHA...

Page 6: ...ied must be regularly inspected Defective or worn parts must be replaced Guards motor cover coupling shields connectors have been designed for a safe use of the equipment The manufacturer will not be...

Page 7: ...following safety procedures must be followed ensure a good earth connection and ground the parts to be handled i e solvents materials components and equipment ensure adequate ventilation keep working...

Page 8: ...ure that any relief or drain valves fitted are in good working order HOSES Keep hoses out of circulation areas moving parts or hot surfaces Never expose product hoses to temperature higher than 60 C 1...

Page 9: ...horing methods strong enough to prevent unintended bodily movement of the equipment To avoid risks caused by static electricity the equipment as well as its components must be grounded For the pumping...

Page 10: ...he interesting informations to use correctly the equipment pressure voltage and sometimes the above pictogram The equipment is designed with and consists of high quality materials and components which...

Page 11: ...Before assembly and start up please read and clearly understand all the documents relating to the equipment professional use only THE PICTURES AND DRAWINGS ARE NOT CONTRACTUAL WE RESERVE THE RIGHT TO...

Page 12: ...s Unscrew exhaust valve 6 by holding piston 3 Remove ball 15 Clean the parts and reinstall them Be certain seal 8 is installed Replace the parts if necessary LOWER MOBILE PACKING Unscrew cylinder 2 an...

Page 13: ...g screws CHc 33 Dissociate female yoke 12 from reversing block lever 9 Dismount reversing block by removing screws 10 and 8 Reinstall the new reversing block in the reverse order of the disassembly se...

Page 14: ...22 19 A 2 C 1 A 1 A 1 A 1 A 2 A 2 A 1 C 1 A 1 A 1 A 2 A 1 Index Instruction Description Part number A 1 PTFE grease PTFE grease 10 ml 0 0026 US gal 560 440 101 A 2 Anti seize grease Grease box 450 g...

Page 15: ...nderung Mise jour Update Aktualisierung Actualizaci n KREMLIN REXSON SAMES KREMLIN 10 25 GT 10C50 GT Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto POMPE AIRMIX mod le 10C50 G...

Page 16: ...unting assembly Montageplatte kpl Conjunto de fijaci n 1 6 051 770 101 Plaque d interface Plate Befestigungsplatte Placa 1 7 933 011 279 Vis H 8 x 20 Screw model H 8 x 20 Schraube H 8 x 20 Tornillo ti...

Page 17: ...mpe murale sans filtre Wall mounted pump without filter Wandpumpe ohne Filter Bomba mural sin filtro 1 20 155 580 300 Filtre AIRMIX inox 3 8 voir Doc 573 299 050 AIRMIX filter 3 8 stainless steel refe...

Page 18: ...up Schl ssel f r Sp lmitteltasse Llave para prensaestopa 1 Pi ces de maintenance pr conis es Preceding the index number denotes a suggested spare part Bezeichnete Teile sind empfohlene Ersatzteile Pie...

Page 19: ...Anula 13 05 14 Modif nderung 044 630 400 NC ind 9a Pos 9a 144 630 720 ind 9b Pos 9b Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto MOTEUR A AIR mod le 250 4 AIR MOTOR model 25...

Page 20: ...lterung Uni n hembra 1 13 044 570 900 Fourchette de commande quip e Control fork assembly Umsteuerstange komplett Horquilla de mando equipada 1 14 902 202 002 Anneau truarc Retaining ring Sicherungsri...

Page 21: ...air motor ind 2 4 7 8 13 of the reversing block Servicekit Pos 4 Dichtungssatz Luftmotor Pos 2 4 7 8 13 vom Umsteuerblock Bolsa de mantenimiento nd 4 bolsa de juntas motor nd 2 4 7 8 13 del inversor 1...

Page 22: ...tualizaci n Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto HYDRAULIQUE mod le C50 avec garnitures GT FLUID SECTION model C50 with GT packings HYDRAULIKTEIL Modell C50 Packungen...

Page 23: ...ventil Cuerpo de v lvula 1 6 044 950 215 Clapet de refoulement Exhaust valve Druckventil V lvula de expulsi n 1 7 044 950 007 Presse garniture mobile Wetting cup mobile Sp lmitteltasse mobil Prensa gu...

Page 24: ...hnung Denominaci n Qt 144 950 097 Pochette de joints ind 8 9 10 13 17 20 21 22 24 25 Package of seals ind 8 9 10 13 17 20 21 22 24 25 Dichtungssatz f r Hydraulikteil beinhaltet Pos 8 9 10 13 17 20 21...

Page 25: ...i n 144 630 720 Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto BLOC INVERSEUR REVERSING BLOCK UMSTEUERBLOCK BLOQUE INVERSOR NC NS BLOC INVERSEUR DROIT AVEC DEUX ROULEMENTS RIGH...

Page 26: ...O Ring R 10 x 10 Anillo tipo R 10 x 10 3 13 144 579 911 Goupille fendue pochette de 10 goupilles 1 but e ind 11 Pin package of 10 pins 1 stop ind 11 Splint Satz 10 St ck 1 F hrung Pos 11 Pasador bolsa...

Page 27: ...equipado 1 1b N C N S Corps Body K rper Cuerpo 1 3 N C N S Goupille 4 x 8 Pin 4 x 8 Splint 4 x 8 Pasador 4 x 8 1 N C N S But e coll e sur corps ind 1b Stop glued on part ind 1b Anschlag auf K rper gek...

Page 28: ...11 Modif nderung Mise jour Update Aktualisierung Actualizaci n Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto EQUIPEMENT D AIR pour pompes AIRMIX AIR SUPPLY for AIRMIX pumps LU...

Page 29: ...air 1 4 3 5 bar volant noir voir Doc 573 288 040 Air regulator 1 4 3 5 bar 50 76 psi black knob refer to Doc 573 288 040 Druckminderer 1 4 3 5 bar schwarze Stellglocke siehe Dok 573 288 040 Manorredu...

Page 30: ...ur Update Aktualisierung Actualizaci n KREMLIN REXSON SAMES KREMLIN Pi ces de rechange Spare parts list Ersatzteilliste Piezas de repuesto FILTRE PRODUIT HP mod le 3 8 inox HP FLUID FILTER model 3 8 s...

Page 31: ...valve FF 3 8 BSP Kugelhahn IG 3 8 BSP V lvula AP 3 8 BSP 1 5 050 102 411 Raccord inox M 18 x 125 M 3 8 BSP Adaptor stainless steel double male 18x125 3 8BSP Doppelnippel Edelstahl AG 3 8 BSP M 18x1 2...

Page 32: ...n Qt 11 055 580 201 Embase 3 8 Base model 3 8 Grundblock Modell 3 8 Base tipo 3 8 1 12 055 580 202 Cuve Bowl Filterglocke Cubeta 1 13 055 280 002 Ecrou Nut berwurfmutter Tuerca 1 14 055 190 007 Jonc S...

Page 33: ...creen n 8 210 Sieb Nr 8 210 Tamiz n 8 210 1 7 000 161 112 Tamis n 12 280 Screen n 12 280 Sieb Nr 12 280 Tamiz n 12 280 1 000 161 115 Tamis n 15 360 Screen n 15 360 Sieb Nr 15 360 Tamiz n 15 360 1 000...

Page 34: ...ANUAL IMPORTANT Before assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESE...

Page 35: ...erty due to removal or partial or removal of the guards Make sure that the suction strainer is clean and in good condition Regularly clean it and change it if necessary Flush the pump as often as nece...

Page 36: ...AL IMPORTANT Before assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE...

Page 37: ...does not stop at once when shutting off the spray gun The pump stops only on down stroke Check exhaust valve or valve seal The pump stops only on up stroke Check suction valve or upper cartridge The...

Page 38: ...NAL MANUAL IMPORTANT Before assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE...

Page 39: ...ternating movement the air motor drives the piston of the hydraulic section C The fluid is drawn in L and forced under pressure in N Due to its design the pressure is always the one read on the gauge...

Page 40: ...ilter is supplied with a stainless steel screen n 6 filtration size 168 microns or 85 mesh The screen is recommended for the use of an AIRMIX gun fitted with a nozzle model n 6 If the fluid spraying i...

Page 41: ...valve N 14 Point the spray gun towards the material container and trigger the spray gun until the material flows out regularly WORK 15 Reinstall the ring and the aircap on the spray gun 16 Adjust air...

Page 42: ...utions in the presence of flammable solvents 6 When the solvent flows out regularly close the drain valve 7 Point the spray gun towards the material container and press the gun trigger When the solven...

Page 43: ...ore assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MA...

Page 44: ...sq in 0 4 sq in 1 76 oz 76 per gallon 0 4 US gal 87 psi 870 psi 78 4 dBa 140 F 37 5 lbs Test conditions Noise level Test duration 30 s Motor air pressure 6 bar Material used water Flow rate Pump adju...

Page 45: ...ilter outlet HOSES WITH FITTINGS Pump air supply minimum for a 5 m 16 5 ft length 10 mm 3 8 dia Air hose between GUN AIR regulator and gun 7 mm ID 1 4 dia AIRMIX fluid hose between pump fluid outlet a...

Page 46: ...Surface equipment meant to an area where explosive atmospheres due to gas vapours mists are liable to appear from time to time in usual operating P prod xx bar xx psi Maximum fluid pressure at the pu...

Page 47: ...diagrams is given for information purposes only and hold harmless to SAMES KREMLIN The user is responsible for the extraction and conditioning of the painting area where the equipment is used for wor...

Reviews: