SAMES KREMLIN
- 1 -
N° : 578.008.120-UK-1902
1.
OPERATING PRINCIPLE
The pump (A) consists of :
•
an alternating air motor (B),
•
an hydraulic section (C) mechanically coupled to the air motor (B).
The air motor is supplied with compressed air by means of the regulator (D) (yellow/green knob). The
pressure is read on the gauge (E).
During its alternating movement, the air motor drives the piston of the hydraulic section (C). The fluid is
drawn in (L) and forced under pressure in (N). Due to its design, the pressure is always the one read on
the gauge x pump ratio.
The spray air pressure of the gun is adjusted by means of the regulator (black knob) (F).
⇒
To adjust the fluid flow rate, turn the yellow/green knob (D) - (Gauge E).
⇒
To adjust the spray air, turn the black knob (F) - (Gauge G).
The pumps are intensive™ ones or Flowmax ® ones (with bellows).
2. START UP
2-1 FILLING
INTENSIVE™ PUMP