Operating Instructions
89 / 92
Fault
Remedy
Possible cause
Fault report:
No. 3001
The safety temperature
limiter has tripped.
Turn the appliance off and on.
Contact the authorized Customer Service if
the fault recurs.
Fault report:
No. 3003, 3004
Temperature sensor in
the cooking chamber in
terrupted or short-cir
cuited.
Turn the appliance off and on.
Contact the authorized Customer Service if
the fault recurs.
Type 2011, 2021: If only the upper or lower
area of the cooking chamber is affected, the
appliance can continue to be operated with
the functional area.
Fault report:
No. 3005
Overtemperature in
cooking chamber
Switch off the unit. Open the cooking chamber
door and allow the cooking chamber to cool.
Contact the authorized Customer Service if
the fault recurs.
Fault report:
No. 3006, 5001
Overtemperature in elec
tric compartment
Allow the appliance to cool. Clear the vent
openings. Clean the air filter. Supply adequate
cool air.
Contact the authorized Customer Service if
the fault recurs.
Fault display:
No. 3551, 3552
Settings missing or in
valid.
Notify your authorized customer service rep
resentative.
Fault report:
No. 4001, 4002, 4085
Water pressure insuffi
cient
Open the water tap.
Fault report:
No. 4003
Overtemperature in wa
ter drain
Appliance with water connection: Open the
water tap.
Appliance without water connection: Poor at
least 5 litres of water into the outlet screen in
the cooking chamber.
Contact the authorized Customer Service if
the fault recurs.
Fault report:
Nos. 4042 to 4055
Sensor interrupted or
short-circuited.
Turn the appliance off and on.
Contact the authorized Customer Service if
the fault recurs.
Type 2011, 2021: If only the upper or lower
area of the cooking chamber is affected, the
appliance can continue to be operated with
the functional area.
After startup, a message
appears informing you
that servicing is re
quired.
The specified fan motor
runtime has been
reached.
Notify your authorized customer service rep
resentative.
Seals are subject to wear. If servicing is not
carried out on the motor seal, water may es
cape. This may result in consequential dam
age to the appliance.
Fault report:
Miscellaneous
Miscellaneous
Note the fault number.
Turn the appliance off and on.
If the fault continues to occur, contact autho
rised Customer Service and inform them of
the fault number.
If you cannot remedy the fault,
−
turn off the appliance and disconnect from the mains;
−
do not open the housing but
−
notify the authorised Customer Service and tell them the fault number.
Repairs may only be performed by the authorised Customer Service!