VERTICAL PUMP
RDV - RGV - RCV
RBV - RNV - REV
EN-42
8.2.10.
SUCTION STRAINER AND FILTERS
Check periodically that the solids and/or other foreign objects in the tank don’t clog the filter holes.
Reduction in the free suction surface may cause performance losses or damages to the pump.
8.2.11.
INSTRUMENTATION AND AUXILIARY DEVICES
Check the efficiency of the instrumentation (pressure gauges, etc.) and of the accessories necessary for the adjustment
and proper operation of the pump.