VS20WRF and VS20BRF Installer Manual
Installation - Device Parameters continued
DX
FUNCTION
SYSTEM SETTING
DEFINITION
DEFAULT
D07
Valve protection
0
Disable
1
1
Enable
D08
Frost Set point
5-17 Deg C
Required Temperature for frost
5 Deg
Temperature
protection and holiday mode
D09
Hour Format
0
12
1
1 24
D10
N/A N/A
N/A
N/A
D11
Daylight Saving
0
OFF
1
Time (DST)
1
ON
D12
Heating Set point
5-35 Deg C
Maximum temp that can
35 Deg C
Limit
be set for heating
D13
Cooling Set point
5-40 Deg C
Maximum temp that can
5 Deg C
Limit
be set for Cooling
D14
Floor sensor High
Output relay will be switched off
Limit Temperature
6-40 Deg C
when temp is reached for
27 Deg C
floor protection
D15
Floor sensor Low
Output relay will be switched on
Limit Temperature
6-40 Deg C
when temp is reached for
10 Deg C
floor protection
D16
Floor sensor Limit
Output relay will be switched off
for cooling
6-40 Deg C
when temp is reached for
6 Deg C
floor protection
INSTALLATION