background image

GIRA 
Info

 

 

UP Underfloor Heating Thermostat 

Installation Instructions 

 

 

 

UP Underfloor Heating Thermostat 

Order No.: 0394 ..

 

 
 

Please note: 

The appliance should only be installed or fitted by a professional. The current safety regulations of the 
VDE (German Electricians’ Association) and the local electricity boards must be observed during 
installation. The thermostat corresponds to German norm DIN EN 60730, Type 1, and is radioscreened 
in accordance with VDE 0875 and/or EN 66014. The controller works according to mode of action 1C. 
 
 

1.  Area of Application: 

In the household for the regulation of electrical underfloor heating systems and floor sensor systems. 
 
 

2.  How it Works: 

The underfloor heating thermostat consists of two elements: 
2.1 Control device for setting the desired floor temperature. 
2.2 Remote sensor in the floor for monitoring the set temperature. 
 

2.1  Control Device: 

Use setting knob to adjust to the desired temperature. The number scale on the knob 

, 2, 3, 4, 5 

corresponds to a temperature range of 10-50°C. Please also refer to the manufacturer’s setting 
instructions for your underfloor heating. If the temperature of your floor is below that preset by you, the 
control device demands heat and this state is indicated by the red LED over the setting knob. This 
means that you can see when heating system is using energy. 
The range can also be narrowed down by means of an adjustment to the setting knob, a more detailed 
description of which is given in Item 7. The operational state of your underfloor heating system is 
switched on and off by means of the mains switch. You also have the option of programming a 
temperature reduction, for example for the night hours, by means of an external timer. If such a timer 
has been installed at your home, the time when the temperature reduction is to begin is indicated by 
the green LED over the setting knob. The temperature reduction amounts to approx. 5K. Example: the 
temperature you have preset at the control device is 40°C (=4 on the number scale). This means that 
the temperature of the floor, for example during the night hours, can drop to 35°C without your heating 
system being switched on. Your heating system would only be switched on again if the temperature 
were to fall any lower. 
 

2.2  Sensor: 

The sensor is built into the floor. It monitors the floor temperature preset by you at the control device 
and gives the command to switch the underfloor heating on and off. 
 
 
 
 
 
 
 
 
 

UP Underfloor Heating Thermostat 

12/13 

Page 1 of 5 

Summary of Contents for 0394 Series

Page 1: ... is below that preset by you the control device demands heat and this state is indicated by the red LED over the setting knob This means that you can see when heating system is using energy The range can also be narrowed down by means of an adjustment to the setting knob a more detailed description of which is given in Item 7 The operational state of your underfloor heating system is switched on a...

Page 2: ...e event of repair 4 Instructions for the Fitter The I O switch on the control device is a single pole switch disconnecting the device from the mains and interrupting the electric circuit to the heating resistor in the floor For work on the load circuit the power supply must at all times be disconnected e g the fuse removed The relay contact is closed when the sensor is disconnected when the sensor...

Page 3: ...reened lead should be used Sensor parameters Measuring instrument Ri 1 M Ω Temperature C Resistance kΩ 5 85 279 10 66 785 15 52 330 20 41 272 25 33 000 30 26 281 35 21 137 40 17 085 45 13 846 50 11 277 The resistance values can only be measured when the sensor is disconnected 6 Simplified Diagram Remote Sensor 7 Narrowing Down of the Temperature Range The thermostat is set at the maximum setting r...

Page 4: ...rdance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH Co KG Elektro Installations Systeme UP Underfloor Heating Thermostat 12 13 Page...

Page 5: ...erfloor Heating Thermostat Installation Instructions Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de UP Underfloor Heating Thermostat 12 13 Page 5 of 5 ...

Reviews: