background image

SUN_IS_ electrical_installation_v5.1_06092021

3. 

Insert the box from the mounting hole, connecting the protective pipe "2" using a torsion gland.

4. 

Feed wire "5" through the hole in the structure, leaving an allowance as shown in the picture below.

5. 

Remove the protective pipe "1A" and lead the protective pipe with bundle "1" in the marked holes in
the sauna structure.

Summary of Contents for SunCube

Page 1: ...OWNER S MANUAL Salus SunCube Sauna...

Page 2: ......

Page 3: ...20 280 cm Wire 2x 0 75 mm2 350 cm for HUUM furnace temperature sensor 4 Set 4 self extinguishing protective pipe phi 20 330 cm wire 2x 0 75 2 400 cm for LED lighting left side 5 Wire 5x 4 0 mm2 200 c...

Page 4: ...5 mm 7 pcs Screws for the base of the SOS switch phi 3 8 length 25 mm 4 pcs Screws for temperature sensor HUUM fi 2 8 length 15 mm 2 pcs Screws for HUUM controller phi 3 length 30 mm 2 pcs 16 Clamping...

Page 5: ...uare 7 Wood hole saw 65 mm 8 Cordless drill 9 Chisel 10 Drill bits 2 5 mm 5 mm 10 mm 11 Phillips screwdriver 12 Flathead screwdriver 13 Paper tape 14 Soldering compound 15 Transformer soldering iron 1...

Page 6: ...2x 1 50 mm2 470 cm for the LED lighting supply 2 Arrange and tape the wires as shown in the picture then wrap them all around this will make it easier to lead them through the protective pipe without...

Page 7: ...er core from the wire using pliers 8 Use a wire stripper to remove the insulation from the wires then use a crimping tool to fix the 4 mm2 wire ends on both sides 9 Insert wire 6 into the protective p...

Page 8: ...Solder the ends of the wire at the soldering points using a precision soldering iron Add the wire with the black line to the 13 Repeat the operation for the second LED strip II ARMING AND INSTALLATION...

Page 9: ...harness 1 Protective pipe with wire 3 Furnace power wire 5 NOTE The wires should be routed out of the protective pipes in the box with an allowance as shown in the picture below Harness 1 50 cm count...

Page 10: ...ng hole connecting the protective pipe 2 using a torsion gland 4 Feed wire 5 through the hole in the structure leaving an allowance as shown in the picture below 5 Remove the protective pipe 1A and le...

Page 11: ...allation_v5 1_06092021 10 6 Feed the protective pipe with harness 1 through the vias in the structure as illustrated below 7 Insert protective pipe 1A leaving the black wire from the harness to the SO...

Page 12: ...he structure and lead it outside then put the pipe through the grommets in the structure and lead it up to the top of the sauna 2 Attach the clamp and use it to secure the protective pipe 3 3 Make a h...

Page 13: ...loop on it to prevent it from slipping out during the installation of the wool and the external facade IV LAYING OF LED LIGHT INSTALLATION 4 1 Pull the protective pipe 4 inside the sauna structure un...

Page 14: ...gree angle Then widen it with a phi 10 drill bit NOTE The hole must be drilled precisely at a height of 44 cm from the bench seat and 14 cm from the edge of the door opening it will be covered by the...

Page 15: ...LLATION OF SAUCE BOX SWITCH INSTALLATION 1 Measure 13 cm from the door frame and 13 cm from the underside of the bench Drill a hole for the SOS button box using a hole saw 2 Insert the box into the ho...

Page 16: ...tightened 4 Tack the ends onto the cables and screw to the switch NOTE The wires should be screwed to the side marked in red poles 1 and 2 5 Drill four holes with a 2 5 mm drill bit so that the base i...

Page 17: ...location of the hole for the box so that it is in the middle of the second vertical paneling board IMPORTANT at a height of 56 cm from the underside of the bench Pre drill then use a chisel to deflect...

Page 18: ...he protective pipe 1A and 4 VII DRILLING THE HOLES FOR WIRE 8 OF THE DOOR OPENING DETECTOR HUUM 1 Make a hole with a drill phi 6 mm in the door frame at a height of 72 cm from the threshold of the doo...

Page 19: ...e from the harness and solder them together using a transformer soldering iron 2 Using a cigarette lighter secure the wire connections 3 Glue the ends of the LED strip on both sides using universal si...

Page 20: ...he above steps for the left side connecting to wire 7 IX PREPARATION AND INSTALLATION OF THE ALARM SIREN 1 Cut a 6 cm wide piece from the phi 110 pipe Then make an undercut for the siren wire 2 Make a...

Page 21: ...4 mm length 15 mm 5 Fit double WAGO connectors on each wire 6 Fit 0 75 mm2 cable lugs on wire 3 Then connect the wires from the siren to the harness with WAGO connectors according to the colors in the...

Page 22: ...the wires to make it easier to attach them to the sensor Using a small screwdriver screw them onto the sensor mounts 2 Drill a hole using a drill phi 2 5 then screw in the bottom mounting screw Slide...

Page 23: ...1 2x 0 75 mm2 then solder it to the sensor wire 8 routed through the mounting hole of the box to the door frame 2 Tuck the wire into the mounting hole on the box NOTE The wire should be tucked outside...

Page 24: ...from which the 8 wire protrudes and lubricate the end of the sensor with universal mounting silicone spreading it over the sensor Press it into the mounting hole and clean off any excess silicone 6 S...

Page 25: ...tor 2 ash wire Connector 3 green yellow wire Connector 4 black 2 Check the attachment of the wires to the sensor and tighten the fixing screws if necessary Secure the contacts with PVB varnish 3 When...

Page 26: ...AND MOUNTING OF THE LED LIGHT SWITCH 1 Attach the cable lugs to a Power wire from harness 1 2x 1 5 mm2 b LED wire left 4 c LED wire right 7 2 Use WAGO connector 3 to connect the wires 3 Connect the ph...

Page 27: ...es in the base of the switch 6 Pass the switch with the connected LED light wires through the hole in the base 7 Evenly fit the base to the paneling and drill the screw holes using the same drill bit...

Page 28: ...its place according to the pictures below B Connection of SOS button installation 1 Identify the wire from harness 1 2x 0 75 mm2 to the SOS switch To do this switch on the SOS switch and check with a...

Page 29: ...rom harness 1 with cable lugs 2 Find the wire marked LED in the box and insert the wires in its place D Preparation of the HUMM control unit and its connection to the installation 1 Remove the screws...

Page 30: ...5 1_06092021 29 2 Assemble the torsion glands and rubber glands as shown in the photo 3 Remove the two screws so that there is clearance for the wire Tighten the others including the silver mounting s...

Page 31: ...om harness 1 to the door opening sensor through the small gland at the bottom c Wire from harness 1 to the Wi Fi controller via the small choke from above d Wire from harness 3 to temperature sensor t...

Page 32: ...wire 5 7 Connect the temperature sensor wire T1 and T2 and the door opening wire O1 and O2 according to the diagram in the photo 8 Connect the wire to the Wi Fi controller according to the diagram in...

Page 33: ...place the cover and fasten it with the screws provided Write the sauna s serial number on the cover with a marker and take a photo of the label Send the photo to radoslaw wojcik suncubesauna com E Con...

Page 34: ...21 33 2 Connect the phase wires to the contactor in place of the wires you removed remember to insert the black wire from the photo above 3 Using the 400 V junction block connect the wires from the bo...

Page 35: ...on XIV points A B and C XV FINAL TEST OF THE ELECTRICAL INSTALLATION CONNECTIONS 1 Screw on the furnace wire terminals 5 for voltage test purposes 2 Connect the 400 V power test wire to the wiring in...

Page 36: ...6 Heat the air with a lighter around the HUMM temperature sensor to verify its operation The temperature shown on the display should increase when heated 7 Check the operation of the door closure sen...

Page 37: ...hase on the three wires brown grey black of harness 5 using a tester 10 Disconnect the power supply to the 400 V mains cable 11 Remove the cube from the installation 12 Close the box and turn the cove...