49
Full battery but can only do several
splices
1) When the memory effect occurs when the battery
is reduced or after a long period of storage, the battery
should be completely let go, and then recharge the
battery.
2) Battery worn, change the battery.
3) Use the machine under too low temperature.
Splicing loss is big
1) Clean the V-groove and fiber clamp.
2) Replace the electrode bar, ARC calibration and
electrode stabilize.
3) Cleaving angle of the fiber, discharging condition
and cleaving state will influence the splicing loss.
The monitor is suddenly turned off
If without any operations, monitor will be turned off
automatically within 180s to avoid loss of electricity.
When display screen turns off, LED lights next to the
“turn on/off” key will flicker, and screen can be
opened again by pressing any buttons.