ENGLISH
7
2.9.3
BUILD
UP
OF
EXPLOSIVE
MIXTURE
Ensure
that
pump
casing
and
mechanical
seal
chamber
are
correctly
vented
and
that
pump
will
not
run
dry.
Make
sure
that
the
pump
runs
with
filled
‐
in
suction
and
discharge
lines
to
avoid
build
up
of
an
explosive
atmosphere.
In
addition
it
is
essential
that
auxiliary
sealing
systems
are
properly
filled.
To
avoid
potential
hazards
from
fugitive
emissions
of
vapor
or
gas
to
atmosphere
the
surrounding
area
should
be
correctly
ventilated.
2.9.4
PREVENTING
LEAKAGE
The
pump
must
only
be
used
to
handle
the
liquids
for
which
it
has
been
defined.
If
the
pump
is
installed
outdoor,
make
sure
liquid
containing
parts
are
drained
and/or
protected
against
freezing.
If
leakage
of
liquid
to
the
atmosphere
can
result
in
a
hazard
then
a
leakage
detection
sensor
should
be
installed.
2.9.5
COMPLETE
UNIT
ATEX
certification
for
a
complete
unit
according
to
ATEX
Directive
94/9/CE
is
given
according
to
lower
protection
level
of
the
integrated
component.
This
comment
applies
particularly
to
the
electric
motor
protection.
2.9.6
PUMP
UNIT
DELIVERED
WITHOUT
MOTOR
/
WITHOUT
SENSORS
If
a
partial
delivery
is
required
(electric
motor,
flexible
coupling,
coupling
guard
or
sensor
not
supplied),
an
integration
certificate
will
be
established.
It
will
be
the
integrator’s
responsibility
to
supply
missing
parts
in
order
to
fulfill
ATEX
requirements
for
the
complete
machine.
2.9.7
COUPLING
GUARD
The
coupling
guard
used
in
a
potentially
ATEX
atmosphere
shall
meet
following
requirements
:
Consist
of
non
‐
sparking
material
(e.g
brass),
Must
be
made
of
antistatic
material,
Must
be
designed
in
such
a
way
that
the
rotating
parts
will
not
come
in
contact
with
any
part
of
the
guard
after
a
choc.
2.9.8
MAINTENANCE
TO
AVOID
HAZARD
CREATION
When
a
pump
is
used
in
a
potentially
ATEX
atmosphere
it
is
necessary
to
check
regularly
the
following
parameters
and
respect
a
maintenance
plan
to
ensure
that
the
equipment
runs
in
perfect
technical
conditions.
Following
regular
checks
are
mandatory
:
No
leakage
of
the
shaft
seal,
Ball
bearings
temperature
(on
bracket
housing
surface),
No
cavitations
and
no
abnormal
running
noises,
Correct
position
of
isolating
valves
and
function
of
motorized
valves.
If
some
parts
are
worn
or
working
in
bad
conditions
the
pump
must
be
stopped
immediately
and
put
in
safety
until
maintenance
operations
are
performed.
Origin
of
default(s)
should
be
eliminated.
2.9.9
PREVENTING
SPARKS
CREATION
Necessary
measures
must
be
taken
to
avoid
sparks
creation
in
case
of
external
impact.
Base
plate
and
pumpset
elements
must
be
properly
grounded.
Ensure
continuity
between
components
of
the
group.
It
applies
to
:
‐
Pump
hydraulics,
‐
Coupling
guard,
‐
Motor
frame,
‐
Baseplate.
The
threaded
hole
or
the
earthing
plate
located
on
the
base
plate
should
be
used
to
make
proper
earthing.
3
TRANSPORT
AND
STORAGE
3.1
SAFETY
MEASURES
Never
rest
below
a
suspended
load.
Keep
a
safe
distance
while
the
load
is
being
transported.
Check
equipment
weight
and
choose
slings
and
other
lifting
devices
accordingly.
Lifting
equipments
should
be
in
good
conditions.
Adjust
the
length
of
the
lifting
devices
so
that
pump
or/and
pumps
set
is
moved
horizontally.
Lifting
lugs
or
eyebolts
that
are
sometimes
attached
to
the
pump
or
to
the
motor
should
not
be
used
to
lift
a
complete
pump
set.
They
should
be
used
only
to
lift
pump
parts
during
dismantling
operations.
Use
the
lifting
points
that
are
mentioned
on
the
pump
set
or
refer
to
following
information.
3.2
DELIVERY
After
reception
of
goods,
the
delivered
items
must
be
inspected
for
damage.
Check
that
all
parts
are
present
(check
description
and
quantities
against
delivery/shipping
documents).
If
any
parts
are
damaged,
missing
or
if
transportation
damage
is
visible,
this
should
be
noted
on
the
freight
documentation
or
on
the
delivery
note.
Do
not
separate
attached
documentation
from
the
pump.
Unpack
the
good
and
eliminate
packaging
according
environmental
requirements.
Do
not
remove
caps
from
pump
flanges
if
pump
will
not
be
installed
immediately.
3.3
SHORT
TERM
STORAGE
Leave
piping
connection
caps
fastened
to
keep
dirt
and
foreign
material
out
of
pump
casing
during
storage.
If
the
pump
will
not
be
used
immediately
after
delivery,
it
must
be
stored
in
a
temperate,
dry,
ventilated
location
and
away
from
vibrations.
Turn
the
pump
shaft
at
intervals
(every
month)
to
avoid
brinelling
of
the
bearings
and
the
seal
faces
from
sticking.
Close
protective
packing
when
done.
If
stored
as
described
above,
the
pump
can
be
stored
up
to
6
months.
Consult
SALMSON
for
preservative
procedure
when
a
longer
storage
period
is
required.
3.4
HANDLING
Depending
on
their
design
some
pumps
can
fall
over
before
they
are
definitively
fastened
to
the
floor.
Take
all
necessary
actions
to
ensure
that
no
‐
one
can
be
crushed
while
the
equipment
is
moved.
A
crane
must
be
used
to
lift
all
equipment
exceeding
25Kg.
Palettes,
crates
or
boxes
can
be
moved
or
unloaded
by
using
a
fork
‐
lift
truck
or
a
hoist
depending
on
lifting
devices
available
on
site.
Only
suitable
lifting
gear
and
load
carrying
equipment
with
valid
test
certificates
and
adequate
lifting
capacity
for
the
loads
involved
should
be
used
to
lift
and
carry
the
goods.
Only
authorized
personal
should
proceed
to
pump
transportation
and
they
must
respect
local
regulations.
Weight
of
goods
is
indicated
on
the
delivery
note.
Only
use
suitable
lifting
points
that
are
indicated
on
the
equipment
and
respect
hereafter
lifting
and
transportation
sketches.
Pumps
should
never
be
lifted
directly
with
slings.
Hooks
must
be
used
and
placed
in
dedicated
lifting
holes.
Chose
proper
sling
length
or
use
a
lifting
beam.
Summary of Contents for NOEH
Page 2: ......
Page 3: ...NOEH INSTALLATION ET MISE EN SERVICE FRAN AIS N M S n 4095567 Ed 3 10 13...
Page 4: ...2...
Page 24: ...FRAN AIS 22 13 DECLARATION CE...
Page 25: ......
Page 26: ...NOEH INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH N M S n 4095567 Ed 3 10 13...
Page 27: ...2...
Page 44: ...ENGLISH 19 12 1 1 SECTIONAL DRAWING SINGLE VOLUTE CASING DOUBLE VOLUTE CASING...
Page 46: ...ENGLISH 21 13 EC DECLARATION OF CONFORMITY...
Page 47: ......