background image

REMEDIES

a) Dismantle the pump and clean it.

b) Clean all the pipes.
c) Check the tightness of the whole pipe, up to the pump, and make it tight.
d) Fill the pump to re-prime.  Check that the foot valve is tight.
e) Loss of head on suction or suction height too great (check the NPSH of the pump

installed).

f) Interchange two phase wires on the motor terminal block or circuit-breaker to reverse

the direction of rotation.

g) Check the voltage on the terminals of the motor and the cross-sections of the

conductors.

a) Check the nuts of the stud bolts and tighten them fully.
b) Dismantle the pump and clean it.
c) Check that the pump turns freely without abnormal sticking.
d) Check the connections to the pump.

a) Check the voltage on the terminals of the motor; it should be within ± 10 % of the

rated voltage.

b) Dismantle the pump and clean it.
c) The motor is designed to operate at an ambient temperature of not more than +40°C.
d) To conform to the motor plate.

a) Dismantle the pump and correct the problem.

b) Replace it.
c) Fill the pump and bleed until there are no more air bubbles.
d) Interchange two phase wires on the motor terminal block or on the circuit-breaker to

reverse the direction of rotation.

e) Check the voltage at the terminals of the motor and the cross-section of the

conductors and of the coupling.

a) Check the current with an ammeter, or set to the current rating marked on the motor

data plate.

b) Check that the conductor cross-sections of the power cable are adequate.
c) Check it and, if necessary, replace the power cable.
d) Replace it.

e) Replace it.

a) Reread the installation conditions and recommendations in this data sheet.
b) The suction pipe must have the same diameter as the pump suction port.

c) Remove and clean.

• For the motor and other components, pressure head and ambient

temperature.

• Priming frequency, duty continuous or periodic.

The mechanical seal do not require special servicing in operation.

Bearings are lubricated for lifetime and do not require any
lubrication.

9

8 . OPERATING TROUBLE : 

If the liquid is toxic, corrosive or dangerous for human being,
SALMSON must be informed or the qualified person in
charge of the repairing. In this case, clean the pump to
ensure o complete safety to the repairing man.

TROUBLES

8.1. PUMP TURNS BUT NO

DELIVERY

8.2. THE PUMP VIBRATES

8.3. THE MOTOR

OVERHEATS

8.4. THE PUMP DELIVERS

INSUFFICIENT
PRESSURE

8.5 THE CIRCUIT-BREAKER

DEVICE IS ON

8.6 THE FLOW IS 

IRREGULAR

CAUSES

a) The internal parts are obstructed by

foreign bodies:

b) Suction pipe obstructed:
c) Air leaks in via suction pipe:
d) The pump has lost its priming:
e) The suction pressure is too low; this is

generally accompanied by
cavitation noise:

f) The pump turns the wrong way (three-

phase motor):

g) The supply voltage to the motor is too

low:

a Loose on its foundation:
b) Foreign bodies obstructing the pump:
c) Pump is hard to turn:
d) Incorrect electrical connection:

a) Voltage too low:

b) Foreign bodies obstructing the pump:
c) Ambient temperature above +40°C:
d) Coupling failure in the terminal box:

a) The motor fails to run at its normal

speed (foreign bodies, defective
power supply, etc.):

b) The motor is faulty:
c) Pump poorly filled:
d) The motor turns the wrong way (three-

phase motor):

e) The supply voltage of the motor is too

low:

a) The setting of the thermal relay is too

low (three-phase motor):

b) The voltage is too low:
c) One phase is open-circuit:
d) The thermal relay of the circuit-

breaker is faulty:

e) A fuse is off:

a) The suction height (SH) is exceeded:
b) The diameter of the suction pipe is

smaller than that of the pump:

c) The strainer and suction pipe are

partially obstructed:

For a prolonged shutdown, if there is no risk of frost, it is best not to
drain the pump.
To avoid any blocking of the shaft and the hydraulic system, in frosty
periods, empty the pump by removing the plug (

6

) and the filling

plug (

5

). Screw the 2 plugs back in, without tightening them.

The replacement frequencies for the mechanical seal will depend
on pump operating conditions, namely:

• For the mechanical seal, the temperature and pressure of the

liquid pumped

ENGLISH

Summary of Contents for MUH100

Page 1: ...ONS OF STAINLESS STEEL MULTISTAGE HORIZONTAL PUMPS FRANCAIS ENGLISH INSTALACI N E INSTRUCCIONES DE PUESTA EN MARCHA DE LAS BOMBAS HORIZONTALES MULTICELULARES EN INOX ESPA OL ISTRUZIONI DI MONTAGGIO E...

Page 2: ...INAS E COMPATIBILIDADE ELECTROMAGN TICA POMPES SALMSON declara que os materiais designados no presente cat logo obedecem s disposi es da directiva M QUINAS modificada Directiva 98 37 CEE e COMPATIBILI...

Page 3: ...6 20 mm MIN 5 2 5 1 MOT 230V 1 x 230V MOT 230 400V 220 380V 240 415V 3 x 400V 3 x 380V 3 x 415V 3 x 230V 3 x 220V 3 x 240V 220V 240V 1 x 220V 1 x 240V W2 W1 U1 Y 2 1 7 2 5 4 3 7 6 700 mm MIN 100 mm MI...

Page 4: ...rivi re d un tang A proscrire sur puits Abyssin pieu puits piqu 1 2 Caract ristiques techniques Pression maxi de service 10 bars Plage de temp rature 15 90 C Temp ratureambiante produitstandard 40 C a...

Page 5: ...on la ou les pompe s Aucun entretien particulier en cours de fonctionnement maintenir Par tuyauterie flexible avec h lice de renforcement ou rigide Le diam tre de la tuyauterie d aspiration ne doit ja...

Page 6: ...mpe c La cr pine et la tuyauterie d aspiration sont partiellement obstru es 8 INCIDENTS DE FONCTIONNEMENT Si le liquide est toxique corrosif ou dangereux pour l homme en informer imp rativement SALMSO...

Page 7: ...al pump multistage horizontal 2 to 7 stages depending on model Not self priming Tapped ports axial suction radial discharge in upward direction Shaft sealing by standardized mechanical packing 4 3 The...

Page 8: ...k in only after water flows out and all air has been eliminated Pump in suction Two cases are possible FIRST CASE see FIG 4 1 Close the discharge valve 3 Open the suction valve 2 Unscrew the filling p...

Page 9: ...bricated for lifetime and do not require any lubrication 9 8 OPERATING TROUBLE If the liquid is toxic corrosive or dangerous for human being SALMSON must be informed or the qualified person in charge...

Page 10: ...ra de aspiraci n m xima HC Altura de carga m nima 4 2 La bomba Bomba centr fuga horizontal multicelular 2 a 7 etapas seg n los modelos Sin autocebado Orificios taladrados aspiraci n axial compresi n r...

Page 11: ...de relleno hasta que el agua haya salido y el aire haya sido evacuado completamente Bomba en aspiraci n Dos casos son posibles 1er caso Ver FIG 4 1 Cierre la compuerta de descarga punto 3 Abra la comp...

Page 12: ...saltado un fusible a La altura de aspiraci n no es respetada b La tuber a de aspiraci n es de un di metro inferior al de la bomba c La alcachofa y la tuber a de aspiraci n est n parcialmente obstruid...

Page 13: ...e massima HC Altezza di carico minima 4 2 La pompa Pompa centrifuga orizzontale polistadio 2 a 7 stadi secondo i modelli Non autoadescante Orifizi filettati aspirazione assiale mandata radiale verso l...

Page 14: ...ompleto riempimento della pompa Riavvitare il tappo di riempimento solo dopo lo scarico dell acqua e la completa evacuazione dell aria Pompa in aspirazione Si possono presentare due casi 1 caso Vedi F...

Page 15: ...pulire b Pulire tutto il condotto c Controllare la tenuta stagna di tutto il condotto sino alla pompa e impermeabilizzare d Reinnescarla riempendo la pompa Verificare la tenuta stagna della valvola d...

Page 16: ...E14 2WJ TEL 44 12 83 52 30 00 FAX 44 12 83 52 30 90 PORTUGAL Rua Alvarez Cabral 250 254 4050 040 Porto TEL 351 22 208 0350 FAX 351 22 200 1469 mail salmson pt P S SEA Pte Lte SINGAPORE 1 Claymore Driv...

Reviews: