salmson ALTI-HU VARIO Series Installation And Starting Instructions Download Page 16

16

English

6.3.4  Manual mode

You can access to this mode via the push-button

. The led         is off.

This mode is fugitive and you shall keep pushing
on the push-button         . to get it working. The
pump starts at maximum frequency. When relea-
sing it the pump slows down up to complete
stop.

6.3.5  Automatic mode

This mode allows an automatic setting of the
pressure whatever the flow is.
You can access to this mode by pushing on the
push-button         . The led         is on.

7. Installation

7.1  Local

Install the booster in a room that provides an
easy access, well ventilated and frost-proof.
Be sure that the dimension of the technical room
door is adequate to enter a booster.
Adequate space must be provided for mainte-
nance work. An easy access to the installation
shall be ensured from at least two sides.

7.2  Assembling

Assembling on well smooth and horizontal floor
with fixing per foundation bolts. Plan insulating
material (cork or reinforced rubber) under the
concrete pad to avoid any emission of water cir-
culating noise.

7.3  Hydraulic connection

ATTENTION!

Observe the requirements from the

water supply companies and the local rule into
force.

-  The connection of the suction and delivery mani-

folds can be made either on the right or left hand
sides of the installation. It is recommended to
close the ports that are not used with thread caps.

-  Valves must be fitted on the manifolds to easily

separate the booster if need be.

-  The installation must be fitted with at least one

diaphragm pressure tank to be assembled on the
delivery manifold, 18 and 24 litre capacities, just
beside the booster for higher capacities.

-  The existing pipes must be installed free from

stresses. Compensators or flexible connecting
pipes are recommended for this purpose in order
to avoid stresses on the pipe connections and
minimise the transmission of vibrations to the
building installation.

Connection to public water supply

Be sure the installation can withstand the maxi-
mum pump pressure at zero flow plus the public
water mains pressure. Otherwise connect the
pressure relief valve to the booster outlet.
We recommend to install a pressure relief and
regulating valve on the booster inlet, on the
water supply inlet to avoid any pressure varia-
tions at the booster inlet.

Connection on load to a tank

Be sure the installation can withstand the maxi-
mum pump pressure at zero flow plus the public
water mains pressure. Otherwise connect the
pressure relief valve to the booster outlet behind
the tank.

Connection on suction to a tank

Be sure that the losses of head do not exceed
the suction capacity of the pumps. It is recom-
mended to use a foot-strainer valve with a pipe
whose dimension is equal to or higher than the
suction nominal diameter.

7.4  Electrical connection

WARNING!

The electrical connection must be

performed according to the local regulations by
an electrical installation engineer approved by
the local utility.

To make the electrical connection, the corre-
sponding installation and operating instructions
and attached electrical circuit diagrams must be
observed. General points to be considered are
listed below:

•  the type of current and voltage of the mains

connection must comply with the data on the
type plate and the circuit diagram of the control
unit.

•  as protection measure, the booster must be

earthed according to the regulations (i.e. accord-
ing to the local regulations and circumstances);
the connections intended for this purpose are
identified accordingly (see circuit diagram).

Power supply cable

The electric supply cable shall be correctly
dimensioned according to the total booster
power (see type plate).
Connecting the control box on a voltage differ-
ent from the one mentioned in the description is
not possible (see chapter 5.2. technical data).

NOTA: for any further details an electric diagram
is available inside the control box.

ATTENTION!

Do not forget to connect the earth

terminal.

Lack of water protection

An input ON/OFF (250v 2A) (Fig. 6) protects the
booster against lack of water, a pressure switch
(Normally Open) or a float switch shall be con-
nected to this input.

ATTENTION!

Do not apply external voltage to

the terminals.

auto

auto

auto

auto

POMPES SALMSON SAS 04/2013

Summary of Contents for ALTI-HU VARIO Series

Page 1: ...N M S STOCK N 4 168 504 Ed 3 04 13 ALTI HU VARIO INSTALLATION ET MISE EN SERVICE INSTALLATION AND STARTING INSTRUCTIONS FRAN AIS ENGLISH INSTALLAZIONE E MESSA IN SERVIZIO ITALIANO...

Page 2: ...Fig 1 Fig 2 3 9 1 7 1 2 5 6 2 4 8...

Page 3: ...Fig 3 Fig 5 Fig 6 MAX MIN Fig 4 Acson Vario auto auto 235 262 262 196 G11 4 G11 4 1 3 4 2 6 7 5 2 3 1...

Page 4: ...t tre les suivants d faillance de fonctions importantes de la pompe ou de l installation d faillance du processus d entretien et de r pa ration prescrit dangers pour les personnes par influences lec t...

Page 5: ...essoires Obligatoires R servoir vessie Kit manque d eau ville ou b che Optionnels Vannes d isolement Manchettes anti vibratoires D tendeur de pression Contre brides au diam tre du collecteur 6 Descrip...

Page 6: ...RES a atteint la pression de consigne P REF et que le d bit est nul L Acson Vario assure la protection de la pompe contre 10 2 Le manque d eau Les surintensit s Les temp ratures d eau excessives Le g...

Page 7: ...AVANT ARR T 5 S TPS AVANT ARR T Temporisation avant l arr t de la pompe et apr s la d tection d absence de d bit AFFICHAGE STANDARD AFFICHAGE D fini le mode d affichage Standard Pression R f bar Press...

Page 8: ...ation peut supporter la pression maxi de la pompe d bit nul major e de la pression d eau de ville Dans le cas contraire raccorder un d tendeur de pression la sortie du surpresseur Nous vous recommando...

Page 9: ...rifier l amor age Au besoin tester les pompes l une apr s l autre En aspiration sur b che Fermer la vanne au refoulement Ouvrir la vanne l aspiration D visser les bouchons de remplissage et les enleve...

Page 10: ...montage de la pompe D faut bobinage D connecter le bornier du moteur con cern et contr ler le r seau aux bornes et l isolement du stator remplacer le moteur si n cessaire Manque de pression au refoul...

Page 11: ...par des techniciens locaux et ou le service client le de Salmson Pour viter les demandes de pr cision et com mandes erron es veuillez indiquer toutes les donn es de la plaque signal tique lors de cha...

Page 12: ...y functions failure of the maintenance and repairing process recommended danger to persons due to electrical mechanical and bacteriological influences material damages 2 4 Safety precautions for the o...

Page 13: ...nifold diameter 6 Description and operation 6 1 General description The booster is a compact installation that is sup plied completely piped up and ready to connect The only connections that have to b...

Page 14: ...set point pressure P SET and when the flow is zero The Acson Vario protects the pump against 10 2 dry running over currents too high water temperatures frost short circuits over voltages Under voltage...

Page 15: ...tarting pressure setpoint pressure start delta P TIME BEFORE STOP 5 S TIME BEFORE STOP Time setting before pump stop when there is no flow STANDARD DISPLAY DISPLAY Define the display mode STANDARD pre...

Page 16: ...ter mains pressure Otherwise connect the pressure relief valve to the booster outlet We recommend to install a pressure relief and regulating valve on the booster inlet on the water supply inlet to av...

Page 17: ...k Close the delivery valve Open the suction valve Screw off the filling plugs and remove them With a funnel placed inside the port fill in slowly and completely the pumps and the suction pipes After w...

Page 18: ...connect the terminal block of the motor concerned Check the network at the terminals and the stator insulation Replace the motor if necessary No delivery pressure Flow higher than booster capabilities...

Page 19: ...Spare parts All spare parts must be ordered through Salmson Customer Services In order to avoid any mistakes please specify the name plate data for orders Subject to technical alterations POMPES SALMS...

Page 20: ...a di cautela pu portare a problemi come guasto di importanti funzioni della pompa o del l impianto mancato rispetto del processo di manutenzione e riparazione pericolo alle persone dovuto ad influenze...

Page 21: ...razione Valvola sfogo pressione Controflange in base a diametro collettore 6 Descrizione e funzionamento 6 1 Descrizione generale Il booster un assieme compatto che viene forni to munito di tubazioni...

Page 22: ...pianto P RES ha raggiunto la pres sione di consegna P REF e che il flusso nullo Acson Vario garantisce la protezione della pompa contro 10 2 La mancanza d acqua Le sovraintensit Le temperature d acqua...

Page 23: ...S TPS PRIMA DELLA SENTENZA Temporisation prima dell arresto della pompa e dopo l individuazione d assenza di flusso VISUALIZZAZIONE STANDARD VISUALIZZAZIONE Definito il modo di visualizzazione Standa...

Page 24: ...uesto ingresso ATTENZIONE Non applicare voltaggio esterno ai terminali 6 3 4 Modo Manuale Questo modo accessibile con la chiave La spia luminosa allora estinta fuggevole e pu essere ottenuto soltanto...

Page 25: ...vitare i tappi di riempimento e rimuoverli Con un imbuto posizionato all interno della porta riempire lentamente e completamente le pompe e le tubazioni di aspirazione Dopo l uscita dell acqua e dell...

Page 26: ...la pompa Guasto avvolgimento Scollegare la morsettiera del motore in questione Controllare i collegamenti presso i terminali e l isolamento dello statore Sostituire il motore se necessario Mancanza di...

Page 27: ...ono essere ordinate presso il Servizio Assistenza Clienti Salmson Per evitare richieste di chiarimenti ed errate ordi nazioni necessario indicare all atto dell ordina zione tutti i dati della targhett...

Page 28: ......

Page 29: ...n i n g s 2006 95 EG El e k t r o m a g n e t i s k K o m p a t i b i l i t e t 2004 108 EG De t v e r e n s s t m m e r v e n m e d f l j a n d e e u r o p e i s k a s t a n d a r d e r s o m n m n...

Page 30: ...30 POMPES SALMSON SAS 04 2013...

Page 31: ...31 POMPES SALMSON SAS 04 2013...

Page 32: ...80 380 FAX 39 059 280 200 info tecniche salmson it QUESTO LIBRETTO D USO DEVE ESSERE RIMESSO ALL UTILIZZATORE FINALE E RIMANERE SEMPRE DISPONIBILE SUL POSTO Questo prodotto stato fabbricato in un sito...

Reviews: