background image

 

13

• 

Ensure the supply connection point; test point and natural gas regulator adjustment screw (for 
Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the 
installed position. 

NG Regulator and pressure test adapter should be provided by installer.

• 

Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B. Any hose 
assembly used must be restrained from accidental contact with the flue outlet of an under bench 
oven. 

• 

Prior to connecting the appliance check that the data on the rating plate affixed to the bottom of 
the appliance, correspond to those of the gas mains. 

• 

A duplicate Data Label is supplied to adhere in an accessible area next to the appliance. 

• 

This appliance is suitable for Natural Gas and Universal LPG; ensure that the available gas supply 
matches the Data Label.

• 

Once installed and connected to gas, check there are no leaks using a soapy solution (never a 
flame).

• 

Do not modify this appliance.

10

F I G U R E

mm

This hose assembly shall be suitable for con-
nection to a fixed consumer piping outlet  
located as shown in (fig. 10) 
Hotplates at a point 800 mm to 850 mm above 
the floor and in the region outside the width of 
the appliance to a distance of 250 mm.

Denotes region for flexible hose.

The gas connection is situated at the rear of the appliance, 105mm from the right side and 45mm from 
the rear of the hotplate.
There are two ways to carry out the connection to the main gas line:
a) The hotplate can be connected with rigid pipe as specified in AS5601.
b) The hotplate can be connected with a Flexible Hose, which complies with AS/NZS 1869 (AGA Ap-
proved), 10mm ID, class B or D, no more than 1.2m long and in accordance with AS5601. Ensure that 
the Hose does not contact the hot surfaces of the hotplate, oven, dishwasher or other appliance that 
may be installed underneath or next to the hotplate. 
WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue or flue 
outlet of an under bench oven. The hose should not be subjected to abrasion, kinking or permanent 
deformation and should be able to be inspected along its entire length. 
Unions compatible with the hose fittings must be used and connections tested for gas leaks. The  
supply connection point shall be accessible with the appliance installed. The appliance’s gas inlet 
fitting is a ½” male threaded cylindrical gas type.

Summary of Contents for SCG-4622B

Page 1: ...GAS HOB COOKTOP User Installation Manual SCG 4622B SCG 4625B WWW SALINI COM AU...

Page 2: ......

Page 3: ...FICATION DECLARATION OF CONFORMITY DISPOSAL 4 5 6 14 6 6 7 8 7 7 9 10 16 10 11 11 12 14 14 15 15 16 16 18 19 20 20 Installation of the appliance must be only be undertaken by a licensed installer This...

Page 4: ...ts subject to certain exclusions the foregoing does not affect your statutory rights Before this appliance left the factory it was tested and set by specialised expert personnel to guarantee the best...

Page 5: ...ensure that they are kept under close supervision at all times Children should be supervised to ensure that they do not play with the appliance Cleaning and user maintenance shall not be carried out...

Page 6: ...2 75 Universal LPG 1 00 Natural 0 69 1 15 6 3 6 3 3 Auxiliary 2 75 Universal LPG 1 00 Natural 0 53 0 85 3 6 3 6 4 Wok 2 75 Universal LPG 1 00 Natural 1 05 1 80 14 6 14 6 APPLIANCE OPERATION APPLIANCE...

Page 7: ...should be observed at the end of use to ensure that the knobs are correctly switched off BURNER IGNITION The ignition control is integrated within each of the control knobs Locate the corresponding c...

Page 8: ...mportant for anyone who operates the appliance understands and follows these recommendations Do not place anything eg Flame tamer asbestos mat between pan and pan support as serious damage to the appl...

Page 9: ...en undergoing cleaning or maintenance to avoid electric shock HOB The surface of the hob pan supports enameled burner caps C and burner heads T should be cleaned after each time they are used with war...

Page 10: ...be left anywhere within easy reach of children as they are a potential choking hazard UNPACKING THE APPLIANCE Once the outer wrapping and the inner wrappings of the various parts have been removed che...

Page 11: ...f the modular cabinet and into which the hob will be recessed are indicated in fig 6 depending on model size Cupboards or hoods have to maintain a least distance of 600mm 750 mm from the top Check dim...

Page 12: ...sing it in place with the fingers Remove the strip of protective paper from the seal Insert the hooks into their relative housings K on the hob and set this into the hole in the cabinet Lock it in pla...

Page 13: ...n fig 10 Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the appliance to a distance of 250 mm Denotes region for flexible hose The gas connection is situa...

Page 14: ...ersal LPG or vice versa GAS CONVERSION INSTRUCTIONS The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural gas to Universal LPG or from Universa...

Page 15: ...ian will have to connect a cable with a suitable cross section keeping the earth wire longer than the phase wires To replace other gas and electrical components that are lodged inside the hob remove t...

Page 16: ...s not functioning as expected some of the problems can be caused by simple maintenance operations or something that has been forgotten and can easily be resolved without having to call for technical a...

Page 17: ...sentative Refer to below troubleshooting table for possible problems and recommended solutions Problem Possible Cause Recommended Solution More Information No spark when gas control knob depressed No...

Page 18: ...perating instructions utensil choice TROUBLESHOOTING TABLE WARNING Do not attempt to repair the appliance yourself Repairs may only be carried out by service engineers or an authorised service agent P...

Page 19: ...CG 4622B SCG 4625B Product Dimensions 600 520 100 900 520 100 Cut out Dimensions 555x475 857x487 Approx Weight 13 2kg 21 9kg Electrical Connection 220 240V 50Hz 220 240V 50Hz Gas Connection Natural Un...

Page 20: ...surfaces and materials and clearances to range hoods and exhaust fans This appliance must be installed in accordance with AS 5601 Gas Installations for Australia AS NZS 3000 Electrical Installations W...

Page 21: ...21...

Page 22: ...t specifications in this booklet apply to the specific products and models described at the date of issue these specifications or recommendations may change at any time You should check with your Deal...

Reviews: