Salamander Pumps TapBoost TBS15 Installation Manual Download Page 4

TapBoost is an intelligent domestic inline clean water pump intended to 

improve the flow to a single outlet/point of use (such as a tap, shower, toilet 

cistern) which suffers with a poor natural flow. It is suitable for use with mains 

water and tank fed water systems, with water up to 65°C. TapBoost operates 

at 12V DC which is supplied via a 240V AC power supply unit.
TapBoost is not suitable for boosting multiple outlets. If multiple outlets 

suffer from poor natural flow, Salamander Pumps have a range of products 

that are suitable. Please visit 

www.salamanderpumps.co.uk

 for details of our 

full range of products.
For TapBoost to operate, there must be a natural flow rate 

from the outlet of at least 1.2 litres per minute (lpm). Details 

of how to measure the natural flow rate from the outlet can 

be found at 

www.salamanderpumps.co.uk

 or scan the QR 

code to learn how to measure the flow rate. 
When the natural flow rate is at 1.2 lpm TapBoost will increase the flow up 

to 7 lpm (provided there are no restrictions in the pipework/outlet). If the 

natural flow rate is greater than 1.2 lpm TapBoost will increase your outlet 

flow rate up to a maximum of 11 lpm. Refer to Figure 1 below to see how 

much additional flow TapBoost will provide to the natural flow rate at the 

outlet. TapBoost constantly monitors the flow rate and will react accordingly. 

If the flow rate reaches 11 lpm, TapBoost will enter idle mode so as not to 

pump more than 12 lpm to comply with the Water Supply (Water Fittings) 

Regulations 1999. 
TapBoost cannot overcome restricted incoming pipework and replacement 

water pipes should be installed in this scenario. Some outlets are naturally 

restrictive and TapBoost may not be able to add additional flow to these 

types of outlet.

Please read these instruction details carefully as they are intended to ensure this 

product provides long, trouble-free service. Failure to install the unit in accordance 

with the installation instructions will lead to invalidation of the warranty.

1. Product Description

2

Figure 1 - Additional flow provided by TapBoost

Low 

flow 

in

Boosted

flow 

out

6

7

8

9

10

11

12

0

1

2

3

4

5

6

7

8

9

10

11

12

Incoming Flow (lpm)

Boosted Flo

w (lpm)

Summary of Contents for TapBoost TBS15

Page 1: ...and warranty guide for TapBoost ISSUE 1 0 March 2022 This document should be given to the end user and retained for future reference Should you need to contact Salamander Pumps you will need the below...

Page 2: ...ons and local byelaws Correct installation is essential for safe operation and a trouble free system It is therefore important to read these instructions thoroughly and ensure you comply with them Inc...

Page 3: ...5 Typical Installations 6 6 Additional Safety Instructions for 8 Bathroom Shower Room Installations 7 Lighting Codes 9 8 Commissioning 10 9 Maintenance 10 10 Standards and Approvals 10 11 General Spec...

Page 4: ...there are no restrictions in the pipework outlet If the natural flow rate is greater than 1 2 lpm TapBoost will increase your outlet flow rate up to a maximum of 11 lpm Refer to Figure 1 below to see...

Page 5: ...factory Some residual water may be present within the pump Important safety information Only the Power Supply Unit and Mains Power Cable provided must be used to operate TapBoost TapBoost Pump with 0...

Page 6: ...so as to stop airflow for ventilation The installation must comply with any local byelaws the Water Supply Water Fittings Regulations 1999 BS EN 806 and in accordance with IET Electrical Regulations G...

Page 7: ...tallation Solder flux should not come into contact with any part of TapBoost the power supply unit or its power cables Never fit to restrictive or collapsed pipework supply e g lead main When installe...

Page 8: ...d in a bathroom shower room please also take note of the additional safety information in Section 6 Single Taps on Sinks Basins Baths Hot and Cold Hot only Cold only Hot and Cold Hot only Cold only Ho...

Page 9: ...TapBoost and all electrics must be inside Toilets Kitchen Appliances Electric Showers Hot and Cold Hot only Cold only Non return valve on cold Non return valve on hot Thermostatic Mixer Showers Outsid...

Page 10: ...cted against moisture and water The plug must be located outside of the bathroom The installation must be carried out to comply with the latest wiring electrical regulations building regulations and l...

Page 11: ...e When an outlet is opened and water begins to flow TapBoost will begin boosting the flow and the LED will fast flash to indicate Boosting Mode If the outlet is closed TapBoost will enter Standby Mode...

Page 12: ...Commissioning 9 Maintenance If a drop in performance is noted from TapBoost the inlet filter should be checked and cleaned if necessary Scan the QR code to learn how to clean the filter Other than the...

Page 13: ...e for activation 1 2 lpm Backflow protection Integrated non return valve Pump inlet connection 15mm compression Pump outlet connection 1 2 male BSP Pump enclosure protection IPX4 Pump weight 0 6 Kg Mo...

Page 14: ...dropping below 11 lpm Air in system Run water through the system with the pump electrically disconnected for several minutes to clear all air Pump operates with all outlets closed Leak in system Chec...

Page 15: ...o year warranty This warranty will operate from the date of purchase and is subject to the installation guidelines being followed correctly Please complete the warranty registration on our website www...

Page 16: ...en replaced by a type not specified by the Company or if the equipment is incorrectly installed operated or used other than as described in the instruction manual or if any servicing or repair of the...

Page 17: ...anty shall be part of the above period s which remain unexpired d In the event of a claim for repairs or replacement being made under the terms of this Warranty a visit from a Salamander service engin...

Page 18: ...16 Notes...

Page 19: ...17 Notes...

Page 20: ...er your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 51...

Reviews: