Salamander Pumps TapBoost TBS15 Installation Manual Download Page 16

14

To the installer

Please follow the guidelines for installation provided in this brochure and call the PumpWise 

helpline for installation advice.
Once the installation has been completed and the system has been tested to your satisfaction, 

please assist the customer in completing warranty registration.
Please note that Salamander Pumps are able to provide an onsite service visit which may be 

chargeable.

1  The Scope of the Warranty

 

SALAMANDER PUMPED SHOWER SYSTEMS LTD (“the Company”) Warrants subject to 

the terms and conditions below for the Warranty period(s) specified in paragraph 3 that 

the Company shall:

 

Repair or replace free of charge the product(s) specified on the Online Warranty 

Registration or Telephone Warranty Registration any component part thereof (together 

referred as “the equipment”) which shall in the opinion of the Company have proved 

defective by reason only of the Company’s materials or workmanship. The Company shall 

be under no obligation whatsoever under this Warranty to repair or replace equipment 

which has been misused, tampered with, or modified/altered in any way without the 

consent in writing from the Company; or if any component or accessory has been replaced 

by a type not specified by the Company; or if the equipment is incorrectly installed, 

operated or used other than as described in the instruction manual; or if any servicing or 

repair of the equipment shall have been carried out by anyone other than an authorised 

Company dealer appointed by the Company (“dealer”).

 

The Company’s liability under this Warranty is limited to the said repairs or replacement 

and shall under no circumstances extend to any financial loss or damage including 

consequential losses alleged to have been suffered by the claimant.

 

Subject as provided in this warranty and except where the equipment is sold to a person 

dealing as a consumer all warranties, conditions or other terms implied by law are 

excluded to the fullest extent permitted by law.

 

Nothing in this warranty shall exclude liability for death or personal injury caused by the 

Company’s negligence.

2  Terms and conditions

 

This Warranty shall only be enforceable by you if the following terms and conditions have 

been complied with:

 

a.   That the equipment has been installed in accordance with the installation 

instructions, guidance and advice contained within the installation and warranty 

guide and/or provided by the Salamander help desk.

 

b.   You are the original purchaser of the equipment from a dealer and not an assignee or 

subsequent purchaser of the equipment.

15. Warranty Information

Summary of Contents for TapBoost TBS15

Page 1: ...and warranty guide for TapBoost ISSUE 1 0 March 2022 This document should be given to the end user and retained for future reference Should you need to contact Salamander Pumps you will need the below...

Page 2: ...ons and local byelaws Correct installation is essential for safe operation and a trouble free system It is therefore important to read these instructions thoroughly and ensure you comply with them Inc...

Page 3: ...5 Typical Installations 6 6 Additional Safety Instructions for 8 Bathroom Shower Room Installations 7 Lighting Codes 9 8 Commissioning 10 9 Maintenance 10 10 Standards and Approvals 10 11 General Spec...

Page 4: ...there are no restrictions in the pipework outlet If the natural flow rate is greater than 1 2 lpm TapBoost will increase your outlet flow rate up to a maximum of 11 lpm Refer to Figure 1 below to see...

Page 5: ...factory Some residual water may be present within the pump Important safety information Only the Power Supply Unit and Mains Power Cable provided must be used to operate TapBoost TapBoost Pump with 0...

Page 6: ...so as to stop airflow for ventilation The installation must comply with any local byelaws the Water Supply Water Fittings Regulations 1999 BS EN 806 and in accordance with IET Electrical Regulations G...

Page 7: ...tallation Solder flux should not come into contact with any part of TapBoost the power supply unit or its power cables Never fit to restrictive or collapsed pipework supply e g lead main When installe...

Page 8: ...d in a bathroom shower room please also take note of the additional safety information in Section 6 Single Taps on Sinks Basins Baths Hot and Cold Hot only Cold only Hot and Cold Hot only Cold only Ho...

Page 9: ...TapBoost and all electrics must be inside Toilets Kitchen Appliances Electric Showers Hot and Cold Hot only Cold only Non return valve on cold Non return valve on hot Thermostatic Mixer Showers Outsid...

Page 10: ...cted against moisture and water The plug must be located outside of the bathroom The installation must be carried out to comply with the latest wiring electrical regulations building regulations and l...

Page 11: ...e When an outlet is opened and water begins to flow TapBoost will begin boosting the flow and the LED will fast flash to indicate Boosting Mode If the outlet is closed TapBoost will enter Standby Mode...

Page 12: ...Commissioning 9 Maintenance If a drop in performance is noted from TapBoost the inlet filter should be checked and cleaned if necessary Scan the QR code to learn how to clean the filter Other than the...

Page 13: ...e for activation 1 2 lpm Backflow protection Integrated non return valve Pump inlet connection 15mm compression Pump outlet connection 1 2 male BSP Pump enclosure protection IPX4 Pump weight 0 6 Kg Mo...

Page 14: ...dropping below 11 lpm Air in system Run water through the system with the pump electrically disconnected for several minutes to clear all air Pump operates with all outlets closed Leak in system Chec...

Page 15: ...o year warranty This warranty will operate from the date of purchase and is subject to the installation guidelines being followed correctly Please complete the warranty registration on our website www...

Page 16: ...en replaced by a type not specified by the Company or if the equipment is incorrectly installed operated or used other than as described in the instruction manual or if any servicing or repair of the...

Page 17: ...anty shall be part of the above period s which remain unexpired d In the event of a claim for repairs or replacement being made under the terms of this Warranty a visit from a Salamander service engin...

Page 18: ...16 Notes...

Page 19: ...17 Notes...

Page 20: ...er your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 51...

Reviews: