TapBoost is of Class III construction powered by an IEC 60335-1 approved Class II external
power supply providing a SELV output and limited power source (LPS). Note: complete
equipment (TapBoost with power supply) is a Class II product.
Class II - These products usually feature two layers of insulation between live components
and users, which is why they are often known as “double-insulated” appliances.
Class III - Equipment built to the Class III standard is supplied from a special safety
isolating transformer whose output is Separated/Safety Extra-Low Voltage or SELV.
11. General Specification
Part Number
TBS15
Guarantee
2 years
Pump
Specification
Maximum inlet water pressure
10 Bar/1000 kPa
Minimum flow rate for activation
1.2 lpm
Backflow protection
Integrated non-return valve
Pump inlet connection
15mm compression
Pump outlet connection
1/2” male BSP
Pump enclosure protection
IPX4
Pump weight
0.6 Kg
Motor duty rating
Continuous
Boosted output flow rate
7 - 11 lpm (varies depending on incoming flow rate)
Water temperature
4°C - 65°C
Maximum head
5m (0.5 bar)
Full load current
1.5 A
Maximum pump wattage
18 W
Pump dimensions (mm)
95mm(L) x 53mm(W) x 124mm(H)
Power Supply
Transformer
Electrical input
AC 100-240 Volts, 50/60Hz, 1.5A
Electrical output
DC 12 Volts, 60W, 5.0A
Model number
GT-46600-6012-T2 or TP1038-D
Mains power cable
UK 3 pin plug fitted with 3A fuse
Transformer enclosure protection
IPX0 - must be protected from water and moisture
Power supply weight
0.4 Kg
Power supply dimensions (mm)
145mm(L) x 52mm(W) x 34mm(H)
Actual values may vary due to tolerances
Product
Appliance
11
Table 2 - General Specification